The building sector contributes significantly to energy consumption and greenhouse gas emissions, highlighting the importance of improving building energy efficiency and adopting sustainable insulation materials. This study investigates the influence of recycled wood-fibre insulation thickness on heating demand and modelled global warming potential (GWP) for a residential building at Blackevägen 16, Gothenburg, Sweden. Four insulation thicknesses—50 mm, 100 mm, 150 mm, and 200 mm—are evaluated to compare their effects on building heating demand and associated climate impacts. The heating demand is estimated using a degree-day-based calculation method, while the environmental assessment considers insulation production impacts and emissions associated with district heating over a 50-year period. The results indicate that increasing the insulation thickness from 50 mm to 200 mm reduces the estimated annual heating demand from approximately 17,084 kWh to 10,597 kWh, representing a reduction of about 38%. The modelled combined GWP decreases from approximately 47,022.87 kg CO₂-eq for the 50 mm case to 29,309.22 kg CO₂-eq for the 200 mm case, corresponding to a reduction of approximately 37.7%.