Automatic monitoring of bins
Halmstad University, School of Information Technology.
Halmstad University, School of Information Technology.
2020 (English)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

When a pile of scrap at Stena recycling has reached the maximum height, the loader operators need to drive around the facility to check whether or not the pile has to be emptied. This causes a lot of unnecessary driving, resolving in wear to the loaders and loss of time, but mostly the unnecessary use of diesel. In this paper different sensors is evaluated and tested against each other to find a system that can measure the volume of the pile. The sensors used is IFM O3D303 and the Kinect V1 sensor. These sensors are then used with two different volume calculation software, CloudCompare and 3DF Zephyr. The goal of the project is to get a system that can get a volume with an accuracy within 2.5 % of the actual volume. If a volume can be calculated from the scrap piles, then it is also possible to know when the pile should be cleared. Since the facility is a recycling plant, there is a lot of metal dust that is gathering in the indoor part of the facility. The sensors being used, should be able to work in this environment. To do that the sensor needs to have an IP certification higher than IP 55. The distance of measuring the pile can be more than 10 m, so the sensors should also be able to handle this requirement. From the sensors a point cloud and a mesh were captured, two data formats that contain information of where every point on the object is located in a three-dimensional space. Every system needs to be calibrated to suit the specific application. The results show that, even with a basic sensor such as the Kinect V1, an accurate volume of a scrap pile could, with calibration, be calculated. However, the cheap sensor does have limits, unlike the IFM which can cope with all the requirements. This report shows how the two sensors compare to each other and how the different software, combined with the sensors, can be used to calculate a volume of a pile of scrap.

Place, publisher, year, edition, pages
2020.
National Category
Environmental Management
Identifiers
URN: urn:nbn:se:hh:diva-42986OAI: oai:DiVA.org:hh-42986DiVA, id: diva2:1461220
External cooperation
Stena Recycling AB
Educational program
Mechatronic Engineer, 180 credits
Supervisors
Examiners
Available from: 2020-05-20 Created: 2020-08-26 Last updated: 2025-10-01Bibliographically approved

Open Access in DiVA

fulltext(9549 kB)551 downloads
File information
File name FULLTEXT02.pdfFile size 9549 kBChecksum SHA-512
95952e7e4dfb90c24fd69d4a69512cefaf4acdf8d702fafc132611bd1d7fe94fa7782049940cb62a170bebc59f9b48f2965c07098e5e61076daaedc92e89e37d
Type fulltextMimetype application/pdf

By organisation
School of Information Technology
Environmental Management

Search outside of DiVA

GoogleGoogle Scholar
Total: 560 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 438 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf