hh.sePublications
Planned maintenance
A system upgrade is planned for 17/11-2026, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Energy flexibility using the thermal mass of residential buildings
Halmstad University, School of Business, Innovation and Sustainability.ORCID iD: 0009-0001-0185-373X
Halmstad University, School of Business, Innovation and Sustainability.ORCID iD: 0000-0001-9982-5317
Halmstad University, School of Business, Innovation and Sustainability.ORCID iD: 0000-0003-2885-0923
Halmstad University, School of Business, Innovation and Sustainability.ORCID iD: 0000-0002-7525-6954
2023 (English)In: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 301, p. 1-12, article id 113698Article, review/survey (Refereed) Published
Abstract [en]

The transition to a more sustainable energy system with a growing amount of intermittent renewable energy sources brings an increasing need for flexibility measures to maintain balance between supply and demand. Buildings represent a promising source of demand-side flexibility due to their large energy demand and thermal mass. This review provides insights into the storage potential of building thermal mass, and the benefits and challenges it brings. It is found that building thermal mass storage have good ability to shift loads on short term, from peak to off-peak hours. This ability can be utilized for different purposes, for instance reduced costs for end-users or energy providers, reduced primary energy demand, or reduced CO2 emissions. Furthermore, this review explores different factors that influence the storage potential of building thermal mass, with special attention paid to the heat emission system. It is shown that hydronic floor heating is beneficial compared to radiators since it directly can activate the thermal mass with smaller impact on the indoor temperature. It is also found that the factor with largest impact is the envelope insulation level; increased insulation level brings improved storage efficiency and prolonged thermal autonomy but also decreased storage capacity and increased risk of overheating. Finally, research gaps are identified. © 2023 The Authors

Place, publisher, year, edition, pages
Amsterdam: Elsevier, 2023. Vol. 301, p. 1-12, article id 113698
Keywords [en]
Building thermal mass (BTM), Demand-side management, Energy flexibility, Load shifting, Residential buildings, Thermal energy storage (TES)
National Category
Energy Systems Energy Engineering
Identifiers
URN: urn:nbn:se:hh:diva-52037DOI: 10.1016/j.enbuild.2023.113698Scopus ID: 2-s2.0-85175613669&OAI: oai:DiVA.org:hh-52037DiVA, id: diva2:1813651
Available from: 2023-11-21 Created: 2023-11-21 Last updated: 2026-04-08Bibliographically approved
In thesis
1. Exploring the energy-flexibility potential in the thermal mass of residential buildings
Open this publication in new window or tab >>Exploring the energy-flexibility potential in the thermal mass of residential buildings
2026 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

The striving for a sustainable energy system entails an increasing use of renewable energy. Since several renewable energy sources are non-dispatchable (e.g., wind and solar), this development brings challenges in terms of the balance between energy supply and demand. As a result, there is a growing need for demand-side flexibility.

The building stock has been highlighted as a promising resource of such flexibility; flexibility can be provided by storing heat in the thermal mass of the buildings and using it for load shifting. The heat-storage potential in Building Thermal Mass (BTM) depends on several building properties, including the insulation level of the building envelope, the heat capacity of building structures and indoor content, and the type of heating system. Regarding heating system type, previous studies have shown that floor-heating systems are beneficial compared to radiator systems since they better activate the thermal mass of the building structures.

This work has contributed to a better understanding of the heating system's influence on the energy-flexibility potential of residential buildings using heat storage in BTM. An existing low-energy multi-family house was used as a case building, heated by a Thermally Activated Building System (TABS). The TABS was compared to two other heating systems: an embedded surface system and a radiator system. It was found that the TABS performed best in every studied respect: it had the longest response time, the shortest recovery time, the greatest heat-storage capacity, and the smallest impact on thermal comfort. Furthermore, significant differences in heat-power capacity were observed.

Based on the same case building, the economic potential of load shifting using BTM storage was also investigated, including its impact on thermal comfort. The heat supply was provided by a modelled ground-source heat pump, and the heating system was controlled in response to historical day-ahead electricity prices. Also, the dependence of the economic potential on various limits of maximum allowable heat power was evaluated. The results showed that significant electricity cost savings for heat-pump operation were obtained, with a limited impact on thermal comfort. Furthermore, it was found that the temperature fluctuation caused by load shifting was counteracted by the natural temperature fluctuation resulting from varying internal heat gains.

Finally, the work includes a review of previous studies on the energy-flexibility potential of residential buildings using BTM storage, focusing on heat-storage potential, influencing factors, and associated benefits and challenges. © Johan Lind 2026

Place, publisher, year, edition, pages
Lund: Faculty of Engineering, Department of Energy Sciences, Lund university, 2026. p. 63
Keywords
Building Thermal Mass (BTM), Energy flexibility, Load shifting, Residential buildings, Thermally Activated Building System (TABS)
National Category
Energy Engineering Building Technologies
Identifiers
urn:nbn:se:hh:diva-58762 (URN)
Presentation
2026-03-13, M:B, Ole Römers väg 1F, Lund, 10:15 (English)
Opponent
Supervisors
Note

The thesis work was financially supported by Halmstad University, Sweden (internal founding).

Available from: 2026-04-10 Created: 2026-04-08 Last updated: 2026-04-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Lind, JohanMöllerström, ErikAverfalk, HelgeOttermo, Fredric

Search in DiVA

By author/editor
Lind, JohanMöllerström, ErikAverfalk, HelgeOttermo, Fredric
By organisation
School of Business, Innovation and Sustainability
In the same journal
Energy and Buildings
Energy SystemsEnergy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 374 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf