hh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Patients' experiences of the implantable cardioverter defibrillator (ICD); with a focus on battery replacement and end-of-life issues
Department of Cardiology UHL, County Council of Östergötland, Linköping, Sweden.
Högskolan i Halmstad, Sektionen för hälsa och samhälle (HOS), Centrum för forskning om välfärd, hälsa och idrott (CVHI).
Division of Nursing Sciences, Department of Medical and Health Sciences, Faculty of Health Sciences, Linköping University, Sweden.
Department of Cardiology, Linköping University Hospital, Linköping, Sweden.
2013 (engelsk)Inngår i: Heart & Lung, ISSN 0147-9563, E-ISSN 1527-3288, Vol. 42, nr 3, s. 202-207Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: ICD deactivation at end-of-life is technically uncomplicated. However, it may present a psychological challenge to healthcare professionals, patients, and next-of-kin. Objective: This study explored patients' experiences of complex issues of battery replacement and deactivation of the ICD. Methods: Semistructured interviews were administered to 37 medically stable ICD-recipients. Results: The ICD-recipients lived with an uncertain illness trajectory, but the majority had not reflected on battery replacement or elective ICD deactivation. Healthcare professionals had rarely discussed these issues with patients. However, this was consistent with the ICD-recipients' wishes. Many patients had misconceptions about the lifesaving capacity of the ICD and the majority stated that they would not choose to deactivate the ICD, even if they knew they were terminally ill, and it meant they would receive multiple shocks. Conclusion: The ICD-recipients tended not to think about end-of-life issues, which imply that many patients reach the final stages of life unaware of the option of ICD deactivation. © 2013 Elsevier Inc.

sted, utgiver, år, opplag, sider
Philadelphia, PA: Mosby , 2013. Vol. 42, nr 3, s. 202-207
Emneord [en]
Battery replacement, deactivation, end-of -life, implantable cardioverter defibrillator, patients perspective
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-24326DOI: 10.1016/j.hrtlng.2012.11.006ISI: 000318891000008PubMedID: 23273655Scopus ID: 2-s2.0-84877119404OAI: oai:DiVA.org:hh-24326DiVA, id: diva2:684055
Merknad

This study was funded with grants from the Medical Research Council of Southeast Sweden (FORSS) and the Carl Jönsson's Foundation.

Tilgjengelig fra: 2014-01-07 Laget: 2014-01-07 Sist oppdatert: 2025-10-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Bolse, Kärstin

Søk i DiVA

Av forfatter/redaktør
Bolse, Kärstin
Av organisasjonen
I samme tidsskrift
Heart & Lung

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 287 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf