hh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Surface Topography and Measuring Techniques for Dental Implant Applications – Possibilities and obstacles
Department of Prosthodontics, Faculty of Odontology, Malmö University, Malmö, Sweden.
Högskolan i Halmstad, Sektionen för ekonomi och teknik (SET), Maskinteknisk produktframtagning (MTEK), Funktionella ytor.ORCID-id: 0000-0001-8058-1252
Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
2012 (engelsk)Inngår i: Implant Dentistry Research Guide: Basic, Translational and Clinical Research / [ed] Ahmed Ballo, New York, NY: Nova Science Publishers, Inc., 2012, s. 33-50Kapittel i bok, del av antologi (Fagfellevurdert)
Abstract [en]

Surface topography has long been identified as a crucial parameter for successful osseointegration of oral implants. A paradigm shift occurred during the 1990s, when the huge majority of companies abandoned turned, minimally rough surfaces in favour of moderately rough surfaces. Several machining techniques have been used to increase the roughness from what was achieved with a turning process. An early obstacle was topographical description of surfaces; scanning electron microscopy (SEM) was often used as a description of the surfaces, but this technique provided no quantitative data. Thus it was, in many cases, difficult to know how one surface differed from another. Optical methods were developed during the late 1980s, and then it was possible to evaluate the threaded part of the implants relevant for osseointegration. Currently, general guidelines exist for how to measure implants surfaces, and a set of quantitative parameters have, after extensive research, been recommended for the topographical evaluation. However, the implant surfaces of today are often geometrically complex and include nanometer particles, porosity, coatings and deterministic patterning; thus the demands for new measuring techniques and evaluation methods increase. © 2012 by Nova Science Publishers, Inc. All rights reserved.

sted, utgiver, år, opplag, sider
New York, NY: Nova Science Publishers, Inc., 2012. s. 33-50
Serie
Dental Science, Materials and Technology
Emneord [en]
surface topography, metrology, dental implant, 3D
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-21132Scopus ID: 2-s2.0-84895847118ISBN: 978-1-61942-447-0 OAI: oai:DiVA.org:hh-21132DiVA, id: diva2:588420
Prosjekter
Avancerad ytkaraktäristik för nya funktionella biomaterial
Forskningsfinansiär
Knowledge Foundation, 20100181Tilgjengelig fra: 2013-01-15 Laget: 2013-01-15 Sist oppdatert: 2025-10-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Scopus

Person

Rosén, Bengt-Göran

Søk i DiVA

Av forfatter/redaktør
Rosén, Bengt-Göran
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 406 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf