hh.se
Publikasjoner
vente ...
Enkelt søk
Avansert søk -
Forskningspublikasjoner
Avansert søk -
Studentoppgaver
Statistikk
English
Svenska
Norsk
Jump to content
Endre søk
Søk
Søk
Kun dokumenter med fulltekst i DiVA
Referera
Exportera
BibTex
CSL-JSON
CSV 1
CSV 2
CSV 3
CSV 4
CSV 4
CSV alle metadata
CSV alle metadata version 2
RIS
Mods
MARC-XML
ETDMS
Link to record
Permanent link
https://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-11797
Direct link
https://hh.diva-portal.org/smash/record.jsf?pid=diva2:366935
Referera
Referensformat
apa
ieee
modern-language-association-8th-edition
vancouver
Annet format
apa
ieee
modern-language-association-8th-edition
vancouver
Annet format
Fler format
Språk
de-DE
en-GB
en-US
fi-FI
nn-NO
nn-NB
sv-SE
Annet språk
de-DE
en-GB
en-US
fi-FI
nn-NO
nn-NB
sv-SE
Annet språk
Fler språk
Utmatningsformat
html
text
asciidoc
rtf
html
text
asciidoc
rtf
Skapa
Stäng
Eld utan rök -Temperaturreglering i en vedpanna
Selander, Fredrik
Högskolan i Halmstad, Sektionen för Informationsvetenskap, Data– och Elektroteknik (IDE).
Johnsson, Inge
Högskolan i Halmstad, Sektionen för Informationsvetenskap, Data– och Elektroteknik (IDE).
2004 (svensk)
Independent thesis Basic level (degree of Bachelor)
Oppgave
Abstract [sv]
Many wood furnaces today are short of an active regulation of the air flow. Since the air need during a burning varies, it would be an advantage if the air could be automatically regulated to the level that is needed for the moment. With present technique the air flow to the wood furnace can be regulated with a lambda sensor. The sensor is expensive, approximately ten times more costly than a temperature sensor. The main goal with this thesis work is to examine were a temperature sensor should be placed to function as a reference for the regulation of the air flow and also quantify which influence the regulation has on the CO-emissions and the flue gas loses. The accomplished experiments shows that with a regulated air flow the CO-emissions can be halved and the flue gas losses can be reduced with 20% compared with none regulated air flow.
sted, utgiver, år, opplag, sider
2004.
Emneord [sv]
aktiv reglering, active regulation, vedpanna, wood furnaces, CO-emissioner
Identifikatorer
URN:
urn:nbn:se:hh:diva-11797
Lokal ID: U10827
OAI: oai:DiVA.org:hh-11797
DiVA, id:
diva2:366935
Uppsök
Technology
Merknad
Denna uppsats kan beställas från arkivet / This paper can be ordered from the archive. Kontakta / Contact: arkivet@hh.se
Tilgjengelig fra:
2010-11-09
Laget:
2010-11-09
Sist oppdatert:
2025-10-01
bibliografisk kontrollert
Open Access i DiVA
Fulltekst mangler i DiVA
Av organisasjonen
Søk utenfor DiVA
Google
Google Scholar
urn-nbn
Altmetric
urn-nbn
Totalt: 104 treff
Referera
Exportera
BibTex
CSL-JSON
CSV 1
CSV 2
CSV 3
CSV 4
CSV 4
CSV alle metadata
CSV alle metadata version 2
RIS
Mods
MARC-XML
ETDMS
Link to record
Permanent link
https://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-11797
Direct link
https://hh.diva-portal.org/smash/record.jsf?pid=diva2:366935
Referera
Referensformat
apa
ieee
modern-language-association-8th-edition
vancouver
Annet format
apa
ieee
modern-language-association-8th-edition
vancouver
Annet format
Fler format
Språk
de-DE
en-GB
en-US
fi-FI
nn-NO
nn-NB
sv-SE
Annet språk
de-DE
en-GB
en-US
fi-FI
nn-NO
nn-NB
sv-SE
Annet språk
Fler språk
Utmatningsformat
html
text
asciidoc
rtf
html
text
asciidoc
rtf
Skapa
Stäng
v. 2.47.0
|
WCAG
|
Högskolebiblioteket i Halmstad
|
Info för studenter
|
Info för forskare
|
Logga in
DiVA
Logotyp