hh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Tensile characterization of multi-ply fabric-reinforced cementitious matrix strengthening systems
Qatar University, Doha, Qatar.ORCID-id: 0000-0003-2273-6863
Qatar University, Doha, Qatar.
Nagoya City University, Nagoya, Japan.
2020 (engelsk)Inngår i: Structural Concrete, ISSN 1464-4177, E-ISSN 1751-7648, Vol. 21, nr 2, s. 713-723Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Fabric reinforced cementitious matrix (FRCM) is a composite consisted of high-strength fibers impregnated in a cement-based mortar, and is commonly used for strengthening reinforced concrete and masonry structures. Comprehending the tensile behavior of FRCM is important to achieve a reliable and accurate design of FRCM strengthening systems. The current paper reports on the results of an experimental study on the tensile characterization of FRCM. A total of 40 FRCM specimens (410 × 50 mm, varied in thickness) were prepared and tested. The tensile characterization tests were conducted according to AC 434 guidelines using clevis-grip mechanism. The tests were used to assess the effect of two parameters: (a) fabric type (carbon/glass) and (b) number of fabric plies (one/two/three/four). The results showed that the tensile strength of carbon-FRCM specimens was approximately 1.33 times that of the glass-FRCM counterparts. Three distinct failure modes were observed, namely, (a) ductile fabric slippage in carbon-FRCM (up to three plies of fabric); (b) brittle fabric delamination in carbon-FRCM with four plies of fabric; and (c) brittle fabric rupture in glass-FRCM systems. The FRCM tensile load-carrying capacity had proportionally increased with the number of fabric plies; less significant effect (within 20%) was observed on the corresponding ultimate tensile stresses (considering the net fabric area as the effective area).

sted, utgiver, år, opplag, sider
2020. Vol. 21, nr 2, s. 713-723
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-48990DOI: 10.1002/suco.201900076Scopus ID: 2-s2.0-85071495587OAI: oai:DiVA.org:hh-48990DiVA, id: diva2:1721418
Tilgjengelig fra: 2022-12-21 Laget: 2022-12-21 Sist oppdatert: 2025-10-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Younis, Adel

Søk i DiVA

Av forfatter/redaktør
Younis, Adel
I samme tidsskrift
Structural Concrete

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 24 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf