hh.sePublications
Change search
Refine search result
1 - 6 of 6
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the Create feeds function.
  • 1.
    Averfalk, Helge
    et al.
    Halmstad University, School of Business, Engineering and Science, The Rydberg Laboratory for Applied Sciences (RLAS).
    Ottermo, Fredric
    Halmstad University, School of Business, Engineering and Science, The Rydberg Laboratory for Applied Sciences (RLAS).
    Werner, Sven
    Halmstad University, School of Business, Engineering and Science, The Rydberg Laboratory for Applied Sciences (RLAS).
    Pipe Sizing for Novel Heat Distribution Technology2019In: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 12, no 7, article id 1276Article in journal (Refereed)
    Abstract [en]

    This paper assesses pipe sizing aspects for previously proposed, novel, low heat distribution technology with three pipes. Assessment issues include heat loss, pressure loss, and pipe sizing for different typical pipe configurations. This assessment has been provided by the analysis of a case area with single-family houses. Concerning heat loss, the proposed three-pipe solutions have the same magnitude of heat loss as conventional twin pipes, since lower return temperatures compensate for the larger heat loss area from the third pipe. Regarding pressure loss, the main restriction on the size of the third pipe is limited to the pressure loss in the third pipe. Thermostatic valves to manage the flow rate of the third pipe are advocated, since alternative small pumps have not been found to be commercially available. The pipe sizing recommendation is that the third pipe for recirculation purposes can be two to three standard pipe sizes smaller than the corresponding supply and return pipe, if no prosumer is connected in the heat distribution network.

  • 2.
    David, Andrei
    et al.
    Aalborg Univ, Dept Planning, Copenhagen, Denmark.
    Vad Mathiesen, Brian
    Aalborg Univ, Dept Planning, Copenhagen, Denmark.
    Averfalk, Helge
    Halmstad University, School of Business, Engineering and Science, The Rydberg Laboratory for Applied Sciences (RLAS).
    Werner, Sven
    Halmstad University, School of Business, Engineering and Science, The Rydberg Laboratory for Applied Sciences (RLAS).
    Lund, Henrik
    Aalborg Univ, Dept Planning, Aalborg, Denmark.
    Heat Roadmap Europe: Large-Scale Electric Heat Pumps in District Heating Systems2017In: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 10, no 4, article id 578Article in journal (Refereed)
    Abstract [en]

    The Heat Roadmap Europe (HRE) studies estimated a potential increase of the district heating (DH) share to 50% of the entire heat demand by 2050, with approximately 25–30% of it being supplied using large-scale electric heat pumps. This study builds on this potential and aims to document that such developments can begin now with technologies currently available. We present a database and the status of the technology and its ability of expansion to other European locations by reviewing experiences aimed at further research or application in the heating industry. This is based on a survey of the existing capacity of electric large-scale heat pumps with more than 1 MW thermal output, operating in European DH systems. The survey is the first database of its kind containing the technical characteristics of these heat pumps, and provides the basis for the analysis of this paper. By quantifying the heat sources, refrigerants, efficiency and types of operation of 149 units with 1580 MW of thermal output, the study further uses this data to analyze if the deployment of this technology on a large-scale is possible in other locations in Europe. It finally demonstrates that the technical level of the existing heat pumps is mature enough to make them suitable for replication in other locations in Europe.

  • 3.
    Gong, Mei
    et al.
    Halmstad University, School of Business, Engineering and Science, Biological and Environmental Systems (BLESS), Energy Science.
    Wall, Göran
    Öxbo, Lerum, Sverige.
    Exergy Analysis of the Supply of Energy and Material Resources in the Swedish Society2016In: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 9, no 9, article id 707Article in journal (Refereed)
    Abstract [en]

    Exergy is applied to the Swedish energy supply system for the period 1970–2013. Exergy flow diagrams for the systems of electricity and district heating as well as for the total supply system of energy and material resources for 2012 are presented. The share of renewable use has increased in both electricity and district heat production. The resource use is discussed in four sectors: residential and service, transportation, industry and agriculture. The resource use is also analyzed with respect to exergy efficiency and renewable share. The total exergy input of energy and material resources amounts to about 2700 PJ of which about 530 PJ was used for final consumption in 2012. The results are also compared with similar studies. Even though the share of renewable resource use has increased from 42% in 1980 to 47% in 2012, poor efficiency is still occurring in transportation, space heating, and food production. A strong dependence on fossil and nuclear fuels also implies a serious lack of sustainability. A more exergy efficient technology and a higher renewable energy share are needed in order to become a more sustainable society.

  • 4.
    Mashad Nemati, Hassan
    et al.
    Halmstad University, School of Information Technology, Halmstad Embedded and Intelligent Systems Research (EIS), CAISR - Center for Applied Intelligent Systems Research.
    Laso, A.
    Department of Electrical and Energy Engineering, University of Cantabria, Santander, Spain.
    Manana, M.
    Department of Electrical and Energy Engineering, University of Cantabria, Santander, Spain.
    Pinheiro Sant'Anna, Anita
    Halmstad University, School of Information Technology, Halmstad Embedded and Intelligent Systems Research (EIS), CAISR - Center for Applied Intelligent Systems Research.
    Nowaczyk, Sławomir
    Halmstad University, School of Information Technology, Halmstad Embedded and Intelligent Systems Research (EIS), CAISR - Center for Applied Intelligent Systems Research.
    Stream Data Cleaning for Dynamic Line Rating Application2018In: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 11, no 8, article id 2007Article in journal (Refereed)
    Abstract [en]

    The maximum current that an overhead transmission line can continuously carry depends on external weather conditions, most commonly obtained from real-time streaming weather sensors. The accuracy of the sensor data is very important in order to avoid problems such as overheating. Furthermore, faulty sensor readings may cause operators to limit or even stop the energy production from renewable sources in radial networks. This paper presents a method for detecting and replacing sequences of consecutive faulty data originating from streaming weather sensors. The method is based on a combination of (a) a set of constraints obtained from derivatives in consecutive data, and (b) association rules that are automatically generated from historical data. In smart grids, a large amount of historical data from different weather stations are available but rarely used. In this work, we show that mining and analyzing this historical data provides valuable information that can be used for detecting and replacing faulty sensor readings. We compare the result of the proposed method against the exponentially weighted moving average and vector autoregression models. Experiments on data sets with real and synthetic errors demonstrate the good performance of the proposed method for monitoring weather sensors.

  • 5.
    Möllerström, Erik
    Halmstad University, School of Business, Engineering and Science, The Rydberg Laboratory for Applied Sciences (RLAS).
    Wind Turbines from the Swedish Wind Energy Program and the Subsequent Commercialization Attempts – A Historical Review2019In: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 12, no 4, article id 690Article, review/survey (Refereed)
    Abstract [en]

    This paper summarizes wind turbines of Swedish origin, 50 kW and above. Both the large governmental-funded prototypes from the early 1980s and following attempts to build commercial turbines are covered. After the 1973 oil crisis, a development program for wind turbine technology was initiated in Sweden, culminating in the early 1980s with the 2 and 3-MW machines at Maglarp and Näsudden. However, government interest declined, and Sweden soon lost its position as one of the leading countries regarding wind turbine development. Nevertheless, several attempts to build commercial wind turbines in Sweden were made in the following decades. Most attempts have, like the earlier prototypes, used a two-bladed rotor, which has become synonymous with the Swedish wind turbine development line. The current ongoing Swedish endeavors primarily focus on the niche-concept of vertical axis wind turbines (VAWTs), which is a demonstration of how far from the broad commercial market of Sweden has moved. Thus far, none of the Swedish attempts have been commercially successful, and unlike countries like Denmark or Germany, Sweden currently has no large wind turbine producer. Suggested reasons include early government interventions focusing on two-bladed prototypes and political disinterest, with wind power grants cut in half by 1985, and the domestic industry not being favored in government policies for deploying wind power.

  • 6.
    Möllerström, Erik
    et al.
    Halmstad University, School of Business, Engineering and Science, Biological and Environmental Systems (BLESS), Energiteknik. Uppsala University, Uppsala, Sweden.
    Ottermo, Fredric
    Halmstad University, School of Business, Engineering and Science, Biological and Environmental Systems (BLESS), Energiteknik.
    Hylander, Jonny
    Halmstad University, School of Business, Engineering and Science, Biological and Environmental Systems (BLESS), Energiteknik.
    Bernhoff, Hans
    Uppsala University, Uppsala, Sweden.
    Noise Emission of a 200 kW Vertical Axis Wind Turbine2016In: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 9, no 1, article id 19Article in journal (Refereed)
    Abstract [en]

    The noise emission from a vertical axis wind turbine (VAWT) has been investigated. A noisemeasurement campaign on a 200 kW straight-bladed VAWT has been conducted, and the result hasbeen compared to a semi-empirical model for turbulent-boundary-layer trailing edge (TBL-TE) noise.The noise emission from the wind turbine was measured, at wind speed 8 m/s, 10 m above ground, to96.2 dBA. At this wind speed, the turbine was stalling as it was run at a tip speed lower than optimaldue to constructional constraints. The noise emission at a wind speed of 6 m/s, 10 m above groundwas measured while operating at optimum tip speed and was found to be 94.1 dBA. A comparisonwith similar size horizontal axis wind turbines (HAWTs) indicates a noise emission at the absolutebottom of the range. Furthermore, it is clear from the analysis that the turbulent-boundary-layertrailing-edge noise, as modeled here, is much lower than the measured levels, which suggests thatother mechanisms are likely to be important, such as inflow turbulence.

1 - 6 of 6
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf