hh.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Förutsättningar för absorptionskyla: Examensarbete på Öresundskraft
Halmstad University, School of Business and Engineering (SET), Biological and Environmental Systems (BLESS), Energiteknik.
Halmstad University, School of Business and Engineering (SET), Biological and Environmental Systems (BLESS), Energiteknik.
2014 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Efterfrågan av kyla ökar i Sverige trots det kalla klimatet vilket då medför att behovet av fjärrkyla kan öka. Fjärrkyla är en centraliserad kylproduktion med fördelar som säkrare drift, minskade haverier samt att buller avlägsnas i jämförelse med lokala kylanläggningar. Således är absorptionskyla ett alternativ till fjärrkyla som börjar bli mer och mer intressant för fjärrvärmeintegrering. Syftet med rapporten är att ge företaget Öresundskraft ett underlag över de tekniska och ekonomiska förutsättningarna för absorptionskyla i Helsingborg. Problemställningarna har varit att undersöka: temperaturen på fjärrvärmen som ska användas till absorptionsanläggningen, hur absorptionsmaskinens kylfaktor påverkar förutsättningarna, hur absorptionsanläggningen ska dimensioneras, utreda olika placeringsalternativ för absorptionsanläggningen, om den befintliga ackumulatortanken kan användas i framtiden och om det är lönsamt att investera i en absorptionsanläggning. Problemställningarna besvarades genom intervjuer, sammanställning och beräkning av data, granskning av forskningslitteratur samt annan litteratur. Slutsatser som författarna har kommit fram till är att absorptionsmaskinen ska dimensioneras till 2,2 MW och att den ska placeras på Västhamnsverket. Under de förutsättningar att det fanns tillgång till billig värme samt att driften endast sker på sommaren fick resultatet ett utfall som gav lönsamhet i en absorptionsanläggning.

Abstract [en]

The cooling demand increases in Sweden despite the cold climate, which could cause the increase of district cooling. District cooling is a centralized cooling system with multiple benefits such as safer operations, reduced failures and removal of rumbling that will otherwise occur in local cooling systems. That’s why the absorption chiller is becoming more and more interesting to incorporate indistrict heating.The purpose of this report is to give the company Öresundskraft the technical and economic conditions for absorption cooling in Helsingborg. The main goal with the report have been to investigate: which temperature from the district heating system will be used for the absorptions chiller, how the coefficient of performance affects the conditions of absorption chiller, different dimensions for absorption chiller, different placement options for absorption chiller, if the existing cool water storage tank can be used in the future, is it profitable to invest in an absorption plant. The main goal questions have been answered through interviews, compilation and calculation of data, examination of research literature and other literature. Conclusions the authors were able to find is that the absorption chiller should be sized to 2,2 MW and it should be placed on Västhamnsverket. Under the conditions that there was access to cheap heat and only operating during the summer the result to invest in an absorption plant was profitable.

Place, publisher, year, edition, pages
2014. , 47 p.
Keyword [sv]
Fjärrvärme, Fjärrkyla, Energi, Energiteknik, Absorptionkyla, Kyla
National Category
Energy Engineering Energy Systems
Identifiers
URN: urn:nbn:se:hh:diva-25705OAI: oai:DiVA.org:hh-25705DiVA: diva2:726131
Subject / course
Energy Technology
Supervisors
Examiners
Available from: 2014-06-18 Created: 2014-06-17 Last updated: 2014-06-18Bibliographically approved

Open Access in DiVA

Förutsättningar för absorptionskyla - Examensarbete på Öresundskraft(2577 kB)353 downloads
File information
File name FULLTEXT01.pdfFile size 2577 kBChecksum SHA-512
38da6e730f34e3d7d4a4f21fdb7e1bfeea4fcdd937c801c6334637aa394bdaa0ac5417e3ee19bd034f2e371f11f7865c0244934a4d0a81a966e706a5cf27c306
Type fulltextMimetype application/pdf

By organisation
Energiteknik
Energy EngineeringEnergy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 353 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 471 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf