hh.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Elektrisk integrering och projektering av förnybar energi i svagt lokalt elnät
Halmstad University, School of Business and Engineering (SET).
Halmstad University, School of Business and Engineering (SET).
2012 (Swedish)Independent thesis Basic level (degree of Bachelor), 15 credits / 22,5 HE creditsStudent thesisAlternative title
Electrical integration and windpower simulation of renewable energy in weak local power grid (English)
Abstract [sv]

För att en kvalitativ och driftsäker kraftomvandling från vind till elkraft skall erhållas ställs krav på en mängd olika faktorer. Klimatologiska och tekniska faktorer kräver korrekt dimensionering och anpassning av omvandlingstekniken för att största möjliga energimängd skall kunna omvandlas på ett driftsäkert och energieffektivt vis som vindkraftsägare, nätägare kräver. Vinden är som bekant en oberäknelig kraftkälla. Variationerna i styrka och tid kan innebära en hel del driftoptimeringsproblematik med efterverkningar för vindkraftsverket, nätet och belastningen. Konsekvenserna kan bero på vilken typ av teknik som är installerad i de olika delarna av energisystemet och i områdets elnät. Varierande effektbehov och effektfaktor i tiden har också en signifikant betydelse för elnätets stabilitet. 

Anpassning av drift i elnätet mot den turbulenta vinden ger ofta avvikelser på spänning och effektflöden, speciellt i extrema situationer där svaga elnät existerar. God samverkan med vindkraftverket och nätets varierande aktiva och reaktiva effektbehov till energianvändaren kan ge förutsättningar för god elkvalitet och därmed optimerad och säker drift med få avbrott över tiden. Ofta kan och är det mekaniska, elektrotekniska val i vindkraftverket och tillhörande elsystem som spelar en avgörande roll för hur lönsam investeringen blir under verkets tekniska livslängd. Nätägaren eftersträvar en god interagering mellan elnät och elproduktion som ger upphov till få medeltalsfel mellan avbrott och elfel, detta kallas i branschen för ”Mean time between failures” MTBF. 

Enligt Svensk energi skall långsamma och snabba spänningsvariationer samt övertoner och erforderlig kortslutningseffekt utredas och jämföras mot de krav och villkor som råder vid elektrisk integrering av elproduktion i elnätet. Förstudien har kommit fram till två lämpliga anslutningsförslag med vindkraftsprojektering. Det beskrivs senare i rapporten förslag på två tillhörande Smart Grid varianter med energilagring för anslutningsförslagen i det befintligt svaga lokala elnätet. 

Abstract [en]

To achieve a reliable and qualitative power conversion from the wind into electric power, a variety of factors and demands need to be obtained. Climatological and technological factors requires proper dimensioning and adjustment of the conversion technology, to harvest the greatest possible amount of energy and to be converted in a reliable and energy efficient way, that windmill owners, power grid owners require. The wind is as familiar an unpredictable power supply. The variations in intensity over time could mean a number of drive optimization problems with after-effects of the wind turbine, power grid and load. The consequences may depend on which type of technology that is installed in the different parts of the energy system. The area's power grid and varying power needs with characteristics over time, also has a significant importance. The turbulent wind gives deviations of voltage and power flow, especially in various extreme situations in weak power grids. Good interaction between the wind turbine and power grid with varying active and reactive power demand for the energy users, provides conditions for a good power quality and thus, an optimal and safe operation with few interruptions over time. It can be, and often is the mechanics, electro-technical choices in the wind turbine and associated electrical systems that play a critical role in how profitable installation is during the wind turbines technological life. The power grid owner strives for a good interaction between the power grid and electrical generation which rise for few faults between interruptions and errors. In the branch this is known as "Mean time between failures" MTBF. 

According to the Swedenergy, harmonics, slow and fast voltage variations including required short-circuit power should be investigated and compared with those requirements and terms that prevails with electrical integration of power into the grid. The feasibility study has concluded two suitable power connection proposals including wind mapping research, later in this report it is described and suggested two related Smart Grid variants with energy storage for the two power connection proposals in the existing weak local grid. 

Place, publisher, year, edition, pages
2012. , 125 p.
Keyword [en]
Windpower, Windturbine, Electrical power, Electrotechnical, Renewable energy, Electrical integration, High voltage, Powergrid, Windpower technology, Energy technology, Energy storage, Dynapeaq
Keyword [sv]
Vindkraft, Elkraft, Elektroteknik, Förnybar energi, Elektrisk integrering, Högspänning, Elnät, Vindkraftsteknik, Energiteknik, Energilagring, DynaPeaQ
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering Infrastructure Engineering Energy Engineering Energy Systems
Identifiers
URN: urn:nbn:se:hh:diva-19037OAI: oai:DiVA.org:hh-19037DiVA: diva2:538128
External cooperation
Göteborgs Energi Nät
Subject / course
Energy Technology
Presentation
2012-05-28, N 106, 15:00 (Swedish)
Uppsok
Technology
Supervisors
Examiners
Note
Judith Saari var betygsättare på muntlig presentation.Available from: 2012-06-29 Created: 2012-06-28 Last updated: 2012-06-29Bibliographically approved

Open Access in DiVA

fulltext(8606 kB)765 downloads
File information
File name FULLTEXT01.pdfFile size 8606 kBChecksum SHA-512
4f6a4ceabf961933a9ee309405e41a6717503c34ee7b1afa3dfe10de10dfd794ba31b791601a5b54d13d9fa55147f4fa44cb5466c7b0dfad5192dd56a339483d
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Sporrong, Kristofer
By organisation
School of Business and Engineering (SET)
Other Electrical Engineering, Electronic Engineering, Information EngineeringInfrastructure EngineeringEnergy EngineeringEnergy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 765 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 663 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf