RoDent: Robotic Dentistry : Computer aided dental implant positioning system
Halmstad University, School of Information Science, Computer and Electrical Engineering (IDE).
Halmstad University, School of Information Science, Computer and Electrical Engineering (IDE).
2007 (Swedish)Independent thesis Basic level (degree of Bachelor)Student thesis
Abstract [sv]

A study was carried in conjunction with the Orthodontic department at Halmstad General Hospital in Sweden to investigate the possibility of reducing cost and manufacture time of dental implant drill guides.

The current system involves sending a digital image in STL format to the Materialise factory in Belgium where information of the position of dental implants is translated onto a moulded mouthpiece. Drill guides are placed in the mouth piece which is then returned to the surgeon. The mouthpiece complete with drill guides is then placed in the patients mouth and used as a guide for the implant drill holes. The cost of 10000 sek and a turnaround time of 2 weeks gave rise to the need for a faster and cheaper solution.

A new mouthpiece was designed comprising of a solid cube which could be clearly seen on the x-ray. Linearisation of the cube faces is used to find a reference point from which to drive a 5 axis drilling platform. The mouthpiece is placed in the drill platform which is driven by stepper motors which in turn are controlled by a microcontroller. Co-ordinates are entered via a PC interface. The PC software then translates these co-ordinates into motor steps which are sent to the microcontroller. The drill platform then positions the mouthpiece in order to drill guide holes for the dental implants.

The study showed that the machine design gave an acceptable degree of accuracy and repeatability. Further enhancements could be made by automating the detection of the cube using image analysis techniques. The study was also limited by the lack of graphical and geometrical data concerning the position of the implant. For the purpose of this study the co-ordinates for the implants guides is entered by hand.

It was concluded that further software and hardware enhancement would be needed before the application could be developed commercially.

Place, publisher, year, edition, pages
Högskolan i Halmstad/Sektionen för Informationsvetenskap, Data- och Elektroteknik (IDE) , 2007.
Keywords [sv]
Robotics, Dental implants
Identifiers
URN: urn:nbn:se:hh:diva-1559Local ID: 2082/1940OAI: oai:DiVA.org:hh-1559DiVA, id: diva2:238777
Uppsok
Technology
Available from: 2008-06-18 Created: 2008-06-18 Last updated: 2008-06-18

Open Access in DiVA

fulltext(6159 kB)346 downloads
File information
File name FULLTEXT01.pdfFile size 6159 kBChecksum MD5
4932762599358ad086b428318821e9e667c11f75fd747c4c112dc39bc464f8e07e31716daca102d9a5ba8bc8e41ad666a1306c77de55624217ac1076e8abd51bd597ed810bc045c3ddd598bb6dfce3e5
Type fulltextMimetype application/pdf

By organisation
School of Information Science, Computer and Electrical Engineering (IDE)

Search outside of DiVA

GoogleGoogle Scholar
Total: 346 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 158 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf