Veingeskolan F - Undersökning av inomhusmiljön samt en konstruktionsmässig utvärdering
Halmstad University, School of Business and Engineering (SET).
2007 (Swedish)Independent thesis Basic level (degree of Bachelor)Student thesis
Abstract [sv]

Title: Veingeskolan F - Investigation of the indoor environment and a structural analysis

Method: Complete analysis of structural drawings to determine if the school have been constructed correctly. In my teorethical studies of the drawings I must seek out points that may have been damaged from moisture, this contains a full survey of the foundation, walls and ceiling. To strenghten the data collected from the drawings I must visit the school and do field investigations to find out if the school has any problems with the indoor environment.

Analysis: I determined that we had some damages on specific places, these damages was caused by leaking roofs, a carpet that was tarnished by strong sunlight in connection with some type of glue and also the ventilation that may have been drawing malodorous air from a shaft in the foundation.

Conclusion: I was able to see that the decision to demolish the school was quite drastic, if the county would have done continuous fixups on the construcion when the employes had complained maybe the action to the tear the school down would have been unnecessary. The lack of communication between the two parts lead up to the decision to demolish and build a complete new school.

Place, publisher, year, edition, pages
Högskolan i Halmstad/Sektionen för Ekonomi och Teknik (SET) , 2007.
Keywords [sv]
indoor environment, structural analysis, Veingeskolan
Identifiers
URN: urn:nbn:se:hh:diva-920Local ID: 2082/1280OAI: oai:DiVA.org:hh-920DiVA, id: diva2:238138
Uppsok
Technology
Available from: 2007-08-20 Created: 2007-08-20 Last updated: 2007-08-20

Open Access in DiVA

fulltext(9018 kB)898 downloads
File information
File name FULLTEXT01.pdfFile size 9018 kBChecksum MD5
e929e6569cf11b070bd1abce84152f75a4d0d8e4d36c17eaeb2924ca2644d31fb8d5529fbd32bd37d90e3d24831eab3f0584fdae3a2db77b7f157469a163676fa71ed31d4fb545faecba78fb835b255d
Type fulltextMimetype application/pdf

By organisation
School of Business and Engineering (SET)

Search outside of DiVA

GoogleGoogle Scholar
Total: 898 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 123 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf