hh.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fresh and hardened properties of seawater-mixed concrete
Qatar University, Doha, Qatar.ORCID iD: 0000-0003-2273-6863
Qatar University, Doha, Qatar.
University of Miami, Coral Gables, FL, USA.
University of Miami, Coral Gables, FL, USA.
2018 (English)In: Construction and Building Materials, ISSN 0950-0618, E-ISSN 1879-0526, Vol. 190, p. 276-286Article in journal (Refereed) Published
Abstract [en]

Using seawater for mixing concrete is potentially advantageous from a sustainability perspective. However, the presence of high concentrations of chloride in the seawater can lead to corrosion of steel reinforcement. This issue can be addressed by using non-corrosive reinforcement; e.g., fiber reinforced polymer (FRP) bars. Moreover, the global threat of freshwater scarcity suggests that the use of seawater in concrete mixtures becomes plausible in the future. This paper reports on the results of an extensive experimental study to compare the fresh and hardened properties of freshwater- and seawater-mixed concretes. The experimental program included the following tests: (a) characterization of fresh concrete (slump flow, density, yield, air content, and setting time); (b) mechanical characterization of hardened concrete (compressive strength, splitting tensile strength, and shrinkage); and (c) permeability performance of hardened concrete (rapid chloride permeability, chloride migration, and water absorption). The use of seawater had a notable effect on the fresh concrete properties. Mechanical performance of seawater concrete was slightly lower than that of the freshwater-mixed concrete. The permeability performance of hardened concrete in the two mixtures was similar. Scanning electron microscopy and isothermal calorimetry were used as supplementary tools to better explain the experimental observations. Finally, remedial measures were proposed based on lab trials to improve the properties of seawater concrete.

Place, publisher, year, edition, pages
2018. Vol. 190, p. 276-286
Keywords [en]
Seawater concrete, Fresh concrete properties, Hardened concrete properties, Permeability, Isothermal calorimetry, Scanning electron microscopy (SEM)
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:hh:diva-49000DOI: 10.1016/j.conbuildmat.2018.09.126Scopus ID: 2-s2.0-85053876215OAI: oai:DiVA.org:hh-49000DiVA, id: diva2:1721368
Available from: 2022-12-21 Created: 2022-12-21 Last updated: 2023-02-16Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Younis, Adel

Search in DiVA

By author/editor
Younis, Adel
In the same journal
Construction and Building Materials
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 31 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf