hh.sePublications
Planned maintenance
A system upgrade is planned for 10/12-2024, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Measurement of skills in cardiopulmonary resuscitation-do professionals follow given guidelines?
Division of Cardiology, Sahlgrenska University Hospital, Göteborg, Sweden.ORCID iD: 0000-0002-2160-4562
Halmstad University, School of Health and Welfare. Division of Cardiology, Sahlgrenska University Hospital, Göteborg, Sweden.
Division of Cardiology, Sahlgrenska University Hospital, Göteborg, Sweden.
Division of Cardiology, Sahlgrenska University Hospital, Göteborg, Sweden.
2001 (English)In: European journal of emergency medicine, ISSN 0969-9546, E-ISSN 1473-5695, Vol. 8, no 3, p. 169-176Article in journal (Refereed) Published
Abstract [en]

Since it is suggested that only effective cardiopulmonary resuscitation (CPR) improves survival rates, quality control of training outcomes is important and comparisons between different training methods are desirable. The aim of this study was to test a model of quality assurance, consisting of a computer program combined with the Brennan et al. checklist, for evaluation of CPR performance. A small group of trained medical professionals (cardiac care unit nurses) (n = 10) was used in this pilot study. The result points out several points of concern: half of the participants did not open the airway prior to breathing control. Over 90% of all inflations were ‘too fast’ and 71% were ‘too much’. Only 6.5% of the inflations were correct. On average, the participants made 5.4 inflations per minute. Concerning chest compressions, 40% were ‘too deep’ while only 4% were ‘too shallow’. In spite of the fact that the participants had an average rate at 95 compressions per minute the number of compressions varied between 32 and 51 during 1 minute. When new guidelines are discussed, it would be beneficial if they were tested by a number of people to investigate if following the guidelines is at all possible. © 2001 Lippincott Williams & Wilkins, Inc.

Place, publisher, year, edition, pages
London: Lippincott Williams & Wilkins, 2001. Vol. 8, no 3, p. 169-176
Keywords [en]
adult, article, clinical competence, computer program, education, female, health care quality, human, male, middle aged, nursing, pilot study, practice guideline, quality control, questionnaire, resuscitation, standard, Sweden, Adult, Cardiopulmonary Resuscitation, Clinical Competence, Female, Guideline Adherence, Humans, Male, Middle Aged, Pilot Projects, Practice Guidelines, Quality Assurance, Health Care, Quality Control, Questionnaires, Software, Sweden
National Category
Health Care Service and Management, Health Policy and Services and Health Economy
Identifiers
URN: urn:nbn:se:hh:diva-39360PubMedID: 11587460Scopus ID: 2-s2.0-0035459490OAI: oai:DiVA.org:hh-39360DiVA, id: diva2:1315836
Available from: 2019-05-15 Created: 2019-05-15 Last updated: 2019-05-15Bibliographically approved

Open Access in DiVA

No full text in DiVA

PubMedScopus

Authority records

Axelsson, Åsa B.

Search in DiVA

By author/editor
Thorén, Ann BrittAxelsson, Åsa B.
By organisation
School of Health and Welfare
In the same journal
European journal of emergency medicine
Health Care Service and Management, Health Policy and Services and Health Economy

Search outside of DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetric score

pubmed
urn-nbn
Total: 42 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf