Vital Sign Radar Redesign: Further Development of a Compact, Highly integrated 60 GHz Radar for Human Vital Sign Monitoring
Halmstad University, School of Information Technology.
Halmstad University, School of Information Technology.
2017 (English)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Nowadays, thanks to the modern technologies, the human being has been able todevelop new techniques to solve problems present in the past. Regarding the medicalfield, it is common to use several apparatus in order to measure the vital signs. Themain drawback about the traditional methods employed for this purpose is that theyare invasive towards the patient. However, in this thesis it has been developed afurther design of a radar system so as to be able to measure these vital signs in awireless way.

Based on a 60 GHz frequency modulated continuous wave radar chip, it has been ableto increase the performance of the measurements by adding a second radar chip.Because of this new feature, the radar system is now having a better precision byprocessing greater data matrix to analyse the targets positions and theirmeasurements. In addition, an enhanced MCU has been incorporated in order toavoid performance bottlenecks because it is necessary to handle the processing of thedata received by the two radar chips. Lastly, reducing the sweeping time (periodbetween the lowest frequency broadcast to linearly reach the highest frequencybroadcast) from 20 ms the previous design to 1 ms, which requires higher samplingrate to cover the fast sweep and provide higher flow of information that leads to fasterdetection process.

A 3D design of the prototype has been designed to show the physical appearance itwould have once entering in production. The result is a compact and highlyintegrated radar system which will be able to monitor the heart beating andrespiration frequency of a human being in a range of ten meters.

Place, publisher, year, edition, pages
2017. , 69 p.
Keyword [en]
radar, vital sign measuring, 60 Ghz frequency
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hh:diva-34219OAI: oai:DiVA.org:hh-34219DiVA: diva2:1111147
Subject / course
Electronics
Educational program
Master's Programme in Electronics Design, 60 credits
Supervisors
Examiners
Available from: 2017-06-20 Created: 2017-06-17 Last updated: 2017-10-31Bibliographically approved

Open Access in DiVA

fulltext(3398 kB)29 downloads
File information
File name FULLTEXT03.pdfFile size 3398 kBChecksum SHA-512
c5d842e61851a1721cbf492dd26989dc419d41ac73c8fd92329bc299194232677f9d1a9290accf1f09f7aa66283bbcc42bb12a3d04aa4b5a5a7a68b3acdfed4d
Type fulltextMimetype application/pdf

By organisation
School of Information Technology
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 64 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 230 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf