hh.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Utveckling av metod för benkvalitetsmätning
Halmstad University, School of Business, Engineering and Science.
Halmstad University, School of Business, Engineering and Science.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Utveckling av metod för benkvalitetsmätning (Swedish)
Abstract [en]

Dental implant surgery is performed daily to replace single teeth and entire tooth rows. Implant selection is based on the bone quality of the cortical and trabecular bone in the jaw bone. Usually, the surgeon assesses the bone quality subjectively during drilling in the jaw bone. The aim of this project has been to increase the ability to give the surgeon a direct feedback on the bone quality during threading in a pre-drilled hole, so the right type of dental implant can be chosen. The idea of the project comes from Lennart Carlsson at TL Medical AB, who has developed a custom-made tap that is used together with a drilling machine that measures the torque during threading. Carlsson has done measurements in polyurethane foam with densities of 1050, 500 and 300 kg/m3.

 

Through regression analyzes in MATLAB on Carlsson's measurements, a linear relationship between torque and number of turns the tap has threaded the material was found. The mean slope value of thirteen measurements/density ± SD was 8.0 ± 0.5 Ncm for density 1050 kg / m3. For density 500 kg / m3 the mean was 1.1 ± 0.2 Ncm and for density 300 kg / m3, the mean was 0.3 ± 0.1 Ncm. The relationship varied depending on which density that was investigated but the lowest achieved R2 value was 0.7. The project has resulted in a table of bone quality and maximum torque. The various ranges for maximum torques were divided into bone qualities as follows: Quality 1 ≥ 26 Ncm, 20 < Quality 2 < 26 Ncm, 12 < Quality 3 ≤ 20 Ncm and Quality 4 ≤ 12 Ncm. Own measurements in ribs from calf were performed to compare the results from the table with the reality. Five measurements out of 11 were in accordance with the table regarding bone quality while the other measurements were either one classification higher or one classification lower than the table.

 

The most important findings are the relationship between the torque size during threading and the different material densities and that the custom-made tap produces a linearly increasing torque for each cut threading in the material. The project group realizes that more tests would have to be done, especially on human tissue, to validate the developed bone quality scale.

Place, publisher, year, edition, pages
2017. , 40 p.
Keyword [sv]
tandimplantat, benkvalité, gängtapp
National Category
Mechanical Engineering
Identifiers
URN: urn:nbn:se:hh:diva-33992OAI: oai:DiVA.org:hh-33992DiVA: diva2:1106065
External cooperation
Lennart Carlsson
Subject / course
Mechanical Engineering
Supervisors
Examiners
Available from: 2017-06-21 Created: 2017-06-06 Last updated: 2017-06-21Bibliographically approved

Open Access in DiVA

fulltext(2169 kB)5 downloads
File information
File name FULLTEXT02.pdfFile size 2169 kBChecksum SHA-512
1d443ad8f882eb82bd413d2e1841b5a70e151ee688661b73aef316fc5a0618a9452f878ede0fec704ef795219e3aaa7efde4266e306e6e9cbbeea2f7228217da
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Eriksson, AnnaCarlfjord, Salli
By organisation
School of Business, Engineering and Science
Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 5 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 5 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf