hh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Correlation Between 3000-meter Running Performance, Yo-Yo IR1 & Submaximal Treadmill Jogging Test
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap, Bio- och miljösystemforskning (BLESS).
2016 (engelsk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgave
Abstract [en]

Background: Physiologic functional capacity through maximal oxygen uptake (V̇O2max) can be measured in many different ways depending on sport and qualities needed to be assessed.In handball a demanding 3000 meter (m) running test is used to evaluate V̇O2max. If this test is sport specific or if it could be replaced by a less strenuous test is unknown. Aim: The aim ofthis study was to compare performance on 3000-meter running with predicted V̇O2max from a submaximal treadmill jogging test (SMTJ) and performance of the Yo-Yo intermittentrecovery test 1 (IR1). Methods: Male handball players (n = 12) performed the 3000 m running test, the Submaximal Treadmill Jogging test and the Yo-Yo Intermittent Recovery test level 1. Measurements in seconds (s), ml ∙ kg-1 ∙ min-1 and meters where collected and correlated using Pearson r, interclass correlation. Results: A strong significant linear correlation (p < 0.01) was found between performance in 3000 m running (s) and Yo-Yo IR1 performance (m), r = - 0.724 (r2 = 0.524). A weak, not significant linear correlation (p > 0.05)was found between performance in 3000 m running (s) and predicted V̇O2max from submaximal treadmill test (ml ∙ kg-1 ∙ min-1), r = - 0.309 (r2 = 0.095). Conclusion: According to this study the 3000 m running test could be replaced by the Yo-Yo IR1 test or vice versa in adolescent male handball players. The submaximal treadmill test used in this study had several potential errors in estimating V̇O2max, this is probably the reason why only a weak correlation was found between the SMTJ and the 3000 m running test.

sted, utgiver, år, opplag, sider
2016. , s. 25
Emneord [en]
3000, cooper, yo-yo, intermittent recovery, submaximal, treadmill, handball, maximal oxygen uptake, Vo2max, correlation
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-31875OAI: oai:DiVA.org:hh-31875DiVA, id: diva2:955955
Fag / kurs
Biomedicine Targeting Physical Education
Presentation
2016-08-24, T156, Linjegatan 8, Halmstad, 13:15 (engelsk)
Veileder
Examiner
Tilgjengelig fra: 2016-08-30 Laget: 2016-08-28 Sist oppdatert: 2018-01-10bibliografisk kontrollert

Open Access i DiVA

fulltext(846 kB)124 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 846 kBChecksum SHA-512
f909f90951f6d55c11854fb96d09d8ee21a66cd4c5f5437e180fc5dba3dfb721f7c5c9b46f39c8ac05e4c86f2934ebda9f815fc403e4d5c865fcd89e0c0e573f
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 124 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 261 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf