POWER DEVIATION ANALYSIS OF THE ROCKNEBY WIND FARM
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap, Bio- och miljösystemforskning (BLESS), Energivetenskap.
2015 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

Nowadays the globalization and the economy expansion of the emerging countries demand anincreasing amount of energy. Therefore, energy production as well as the efficiency of energyusage, is essential for future developments of societies. Renewable energies appear as a turnkeysolution that could support the growing demands, and at the same time not being harmful to theenvironment [1]. Within the types of renewable energies, wind energy could be considered asone with large potential.In this paper I present the study of a Swedish wind farm placed in Rockneby.Once the wind turbines were installed and working correctly, a discrepancy between the realenergy obtained and the theoretical energy indicated by the manufacturer was detected. Thestored data in the SCADA system were compared with the values provided by the manufacturerand several analyses were performed. Initially an anomaly in the power residual deviation wasdetected. It was showing an unusual behaviour at high wind speeds. The variation of the airdensity in the wind farm at hub height was considered as a possible reason of the disagreementobserved in the power parameters since the reference density used by the manufacturer was aconstant value calculated in laboratory environment. However, this idea was rejected becausethe power generated in both conditions is similar. The pitch angle was analysed after detectinga significant variations in wind speed measurements made by the anemometer in the turbinenumber three. As a result, it was found a pitch variation in the turbine which seems due to afailure in the anemometer. As a final result, the turbulences were analysed giving as aconclusion that the turbulence intensity were situated around 20%. Therefore, I mainly suggestas a possible explanation of this fact the influence of the turbulence accompanied of a badcalibration or failure in the anemometers.

sted, utgiver, år, opplag, sider
2015. , s. 65
Emneord [en]
Wind farm, turbulences, power deviation, power analysis
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-28453OAI: oai:DiVA.org:hh-28453DiVA, id: diva2:818352
Fag / kurs
Energy Technology
Presentation
2015-06-02, Halmstad, 10:15 (engelsk)
Veileder
Examiner
Tilgjengelig fra: 2015-06-18 Laget: 2015-06-08 Sist oppdatert: 2015-06-18bibliografisk kontrollert

Open Access i DiVA

fulltext(18703 kB)446 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 18703 kBChecksum SHA-512
8a32069ce0b204dbc63e35ec3b673d80f837deb9ede8451b795fdcc8cda938c210ed9bfc2d3bd41ace829dd84c47a83a986d75ecab9fad6c8f3a077a9e42d02d
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 446 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 283 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf