hh.sePublications
System disruptions
We are currently experiencing disruptions on the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Noise Emission of a 200 kW Vertical Axis Wind Turbine
Halmstad University, School of Business, Engineering and Science, Biological and Environmental Systems (BLESS), Energiteknik. Uppsala University, Uppsala, Sweden.ORCID iD: 0000-0001-9982-5317
Halmstad University, School of Business, Engineering and Science, Biological and Environmental Systems (BLESS), Energiteknik.ORCID iD: 0000-0002-7525-6954
Halmstad University, School of Business, Engineering and Science, Biological and Environmental Systems (BLESS), Energiteknik.
Uppsala University, Uppsala, Sweden.ORCID iD: 0000-0003-4951-8831
2016 (English)In: Energies, E-ISSN 1996-1073, Vol. 9, no 1, article id 19Article in journal (Refereed) Published
Abstract [en]

The noise emission from a vertical axis wind turbine (VAWT) has been investigated. A noisemeasurement campaign on a 200 kW straight-bladed VAWT has been conducted, and the result hasbeen compared to a semi-empirical model for turbulent-boundary-layer trailing edge (TBL-TE) noise.The noise emission from the wind turbine was measured, at wind speed 8 m/s, 10 m above ground, to96.2 dBA. At this wind speed, the turbine was stalling as it was run at a tip speed lower than optimaldue to constructional constraints. The noise emission at a wind speed of 6 m/s, 10 m above groundwas measured while operating at optimum tip speed and was found to be 94.1 dBA. A comparisonwith similar size horizontal axis wind turbines (HAWTs) indicates a noise emission at the absolutebottom of the range. Furthermore, it is clear from the analysis that the turbulent-boundary-layertrailing-edge noise, as modeled here, is much lower than the measured levels, which suggests thatother mechanisms are likely to be important, such as inflow turbulence.

Place, publisher, year, edition, pages
Basel: MDPI , 2016. Vol. 9, no 1, article id 19
Keywords [en]
vertical axis wind turbine (VAWT), H-rotor, noise, noise emission, sound power level
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:hh:diva-27523DOI: 10.3390/en9010019ISI: 000369501500013Scopus ID: 2-s2.0-84956619748OAI: oai:DiVA.org:hh-27523DiVA, id: diva2:781889
Funder
StandUpAvailable from: 2015-01-19 Created: 2015-01-19 Last updated: 2023-08-28Bibliographically approved
In thesis
1. Vertical Axis Wind Turbines: Tower Dynamics and Noise
Open this publication in new window or tab >>Vertical Axis Wind Turbines: Tower Dynamics and Noise
2015 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Vertical axis wind turbines (VAWTs) have with time been outrivaled by the today common and economically feasible horizontal axis wind turbines (HAWTs). However, VAWTs have several advantages such as the possibility to put the drive train at ground level, lower noise emissions and better scaling behavior which still make them interesting for research.

The work within this thesis is made in collaboration between the Department of Construction and Energy Engineering at Halmstad University and the Division for Electricity at Uppsala University. A 200 kW VAWT owned by the latter and situated close to Falkenberg in the southwest of Sweden has been the main subject of the research even if most learnings has been generalized to fit a typical vertical turbine. This particular turbine has a wooden tower which is semi-guy-wired, i.e. the tower is both firmly attached to the ground and supported by guy-wires.

This thesis has two main topics both regarding VAWTs: eigenfrequency of the tower and the noise generated from the turbine. The eigenfrequency of a semi-guy-wired tower is studied and an analytical expression describing this is produced and verified by experiments and simulations. The eigenfrequency of the wire itself and how it is affected by wind load are also studied.  The noise characteristics of VAWTs have been investigated, both theoretically and by noise measurement campaigns. Both noise emission and frequency distribution of VAWTs has been studied.

The work has resulted in analytical expressions for tower and wire eigenfrequency of a semi-guy-wired tower as well as recommendations for designing future towers for VAWTs. The noise emission of VAWTs has been studied and proven low compared to HAWTs. The noise frequency distribution of the 200 kW VAWT differs significantly from that of a similar size HAWTs with for example lower levels for frequencies below 3000 Hz.

Place, publisher, year, edition, pages
Uppsala: Uppsala universitet, 2015. p. 61
Series
UURIE / Uppsala universitet, Institutitionen för teknikvetenskaper, ISSN 0349-8352 ; 340-15L
Keywords
VAWT, H-rotor, eigenfrequency, semi-guy-wired tower, noise emission, sound power level
National Category
Energy Engineering
Identifiers
urn:nbn:se:hh:diva-27526 (URN)
Presentation
2015-01-16, Polhemsalen, Ångströmlaboratoriet, Uppsala, 13:43 (English)
Opponent
Supervisors
Funder
StandUp
Available from: 2015-01-22 Created: 2015-01-19 Last updated: 2021-05-11Bibliographically approved
2. Noise, eigenfrequencies and turbulence behavior of a 200 kW H-rotor vertical axis wind turbine
Open this publication in new window or tab >>Noise, eigenfrequencies and turbulence behavior of a 200 kW H-rotor vertical axis wind turbine
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Vertical-axis wind turbines (VAWTs) have with time been outrivaled by the today more common and economically feasible horizontal-axis wind turbines (HAWTs). However, VAWTs have several advantages which still make them interesting, for example, the VAWTs can have the drive train at ground level and it has been argued that they have lower noise emission. Other proposed advantages are suitability for both up-scaling and floating offshore platforms.

The work within this thesis is made in collaboration between Halmstad University and Uppsala University. A 200-kW semi-guy-wired VAWT H-rotor, owned by Uppsala University but situated in Falkenberg close to Halmstad, has been the main subject of the research although most results can be generalized to suit a typical H-rotor.

This thesis has three main topics regarding VAWTs: (1) how the wind energy extraction is influenced by turbulence, (2) aerodynamical noise generation and (3) eigenfrequencies of the semi-guy-wired tower.

The influence from turbulence on the wind energy extraction is studied by evaluating logged operational data and examining how the power curve and the tip-speed ratio for maximum Cp is impacted by turbulence. The work has showed that the T1-turbine has a good ability to extract wind energy at turbulent conditions, indicating an advantage in energy extraction at turbulent sites for VAWTs compared to HAWTs.The noise characteristics are studied experimentally, and models of the two most likely aerodynamic noise mechanisms are applied. Here, inflow-turbulence noise is deemed as the prevailing noise source rather than turbulent-boundary-layer trailing-edge noise (TBL-TE) which is the most important noise mechanism for HAWTs. The overall noise emission has also been measured and proven low compared to similar sized HAWTs.

The eigenfrequencies of a semi-guy-wired tower are also studied. Analytical expressions describing the first-mode eigenfrequency of both tower and guy wire has been derived and verified by experiments and simulations.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2017. p. 89
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1485
Keywords
VAWT, H-rotor, eigenfrequency, semi-guy-wired tower, noise emission, sound power level, microphone array, turbulence intensity, power curve
National Category
Energy Engineering
Identifiers
urn:nbn:se:hh:diva-33834 (URN)978-91-554-9834-4 (ISBN)
Public defence
2017-04-28, Häggsalen, Lägerhyddsvägen 1, Uppsala, 13:00 (English)
Opponent
Supervisors
Funder
StandUp
Available from: 2017-05-11 Created: 2017-05-10 Last updated: 2021-05-11Bibliographically approved

Open Access in DiVA

fulltext(1601 kB)2886 downloads
File information
File name FULLTEXT01.pdfFile size 1601 kBChecksum SHA-512
2843e43af15c3b6af6e47b330abbec829c857f59470d036eabbc72f6ac338dc35a64bf6b4369774a7a7e068696bada850799e464902033c79137cf1a56ea8954
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Möllerström, ErikOttermo, FredricHylander, JonnyBernhoff, Hans

Search in DiVA

By author/editor
Möllerström, ErikOttermo, FredricHylander, JonnyBernhoff, Hans
By organisation
Energiteknik
In the same journal
Energies
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 2903 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 966 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf