hh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Analysis of neuropeptide Y and its metabolites by high-performance liquid chromatography–electrospray ionization mass spectrometry and integrated sample clean-up with a novel restricted-access sulphonic acid cation exchanger
Kaunas University of Technology, Department of Organic Technology, Kaunas, Lithuania.
Bioanalytical Chemistry, AstraZeneca R&D Mölndal, Mölndal, Sweden.
Institut für Anorganische Chemie und Analytische Chemie, Johannes Gutenberg Universität, Mainz, Germany.
Merck KGaA, Specialty Laboratory Products, Darmstadt, Germany.
Vise andre og tillknytning
2000 (engelsk)Inngår i: Journal of Chromatography A, ISSN 0021-9673, E-ISSN 1873-3778, Vol. 890, nr 1, s. 135-144Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A novel restricted access cation exchanger with sulphonic acid groups at the internal surface was proven to be highly suitable in the sample clean up of peptides on-line coupled to HPLC–electrospray ionization (ESI)-MS. Neuropeptide Y (NPY) and several of its fragments in plasma were subjected to the sample clean-up procedure. The peptides were eluted by a step gradient from the restricted access column, applying 10 mM phosphate buffer pH 3.5 from 5 to 20% (v/v) of acetonitrile with 1 M NaCl and transferred to a Micra ODS II column (33×4.6 mm). The separation of the peptides and their fragments was performed by a linear gradient from 20 to 60% (v/v) acetonitrile in water with 0.1% formic acid and 0.01% trifluoroacetic acid in 4 min at a flow-rate of 0.75 ml/min. An integrated and completely automated system composed of sample clean up–HPLC–ESI-MS was used to analyze real life samples. The sample volumes ranged between 20 and 100 μl. Peaks due to the fragments NPY 1–36, 3–36 and 13–36 in porcine plasma were identified by ESI-MS. The limit of detection was in the 5 nmol/ml range. The total analysis required 21 min and allowed the direct injection of plasma. © 2000 Elsevier Science B.V. All rights

sted, utgiver, år, opplag, sider
Amsterdam: Elsevier B.V , 2000. Vol. 890, nr 1, s. 135-144
Emneord [en]
Restricted-access media, Sample handling, Column switching, Neuropeptides, Peptides
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-24121DOI: 10.1016/S0021-9673(00)00639-7ISI: 000088736900014PubMedID: 10976801Scopus ID: 2-s2.0-0343962626OAI: oai:DiVA.org:hh-24121DiVA, id: diva2:679543
Tilgjengelig fra: 2013-12-16 Laget: 2013-12-09 Sist oppdatert: 2018-03-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Lutz, Mareike

Søk i DiVA

Av forfatter/redaktør
Lutz, Mareike
I samme tidsskrift
Journal of Chromatography A

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 194 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf