hh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Optimisation and validation of an automated solid phase extraction technique coupled on-line to enzyme-based biosensor detection for the determination of phenolic compounds in surface water samples
Department of Analytical Chemistry, University of Lund, Lund, Sweden.
Department of Analytical Chemistry, University of Lund, Lund, Sweden.
Department of Analytical Chemistry, University of Lund, Lund, Sweden.
Department of Analytical Chemistry, University of Lund, Lund, Sweden.
Vise andre og tillknytning
1995 (engelsk)Inngår i: Chromatographia, ISSN 0009-5893, E-ISSN 1612-1112, Vol. 41, nr 3-4, s. 207-215Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A fully integrated screening system for phenolic compounds was developed incorporating on-line solid phase extraction, fractionation and biosensor detection. Two different types of biosensors, solid graphite and carbon paste electrodes incorporating the enzyme tyrosinase, were compared and used in the screening system. Interfacing of the solid phase extraction and fractionation with the biosensor detection was given special attention since the biosensors were not compatible with the organic modifier used for desorption of phenols from the solid phase extraction step. The system was validated with conventional analytical techniques. Surface water samples from the Ebro river were spiked with 1,10, and 25μg L−1 of catechol, phenol,p-cresol, respectively. Three out of seven samples were spiked and the correct samples were identified, containing phenols equivalent to the spiked concentrations. © 1995 Friedr. Vieweg & Sohn Verlagsgesellschaft mbH.

sted, utgiver, år, opplag, sider
Heidelberg: Springer Berlin/Heidelberg, 1995. Vol. 41, nr 3-4, s. 207-215
Emneord [en]
Column liquid chromatography, Solid phase extraction, Enzyme-based biosensor detection, Tyrosinase, Phenols
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-24132DOI: 10.1007/BF02267957ISI: A1995RY73400014Scopus ID: 2-s2.0-0029148882OAI: oai:DiVA.org:hh-24132DiVA, id: diva2:679514
Tilgjengelig fra: 2013-12-16 Laget: 2013-12-09 Sist oppdatert: 2018-03-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Lutz, Mareike

Søk i DiVA

Av forfatter/redaktør
Lutz, Mareike
I samme tidsskrift
Chromatographia

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 262 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf