hh.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Virtual Testing for Smart Buildings
INRIA Bordeaux Sud-Ouest Talence, Talence, France.
INRIA Bordeaux Sud-Ouest Talence, Talence, France.
Rice University Houston, Houston, USA.
Högskolan i Halmstad, Akademin för informationsteknologi, Halmstad Embedded and Intelligent Systems Research (EIS), Centrum för forskning om inbyggda system (CERES).
Visa övriga samt affilieringar
2012 (Engelska)Ingår i: 2012 Eighth International Conference on Intelligent Environments / [ed] Randall Bilof, Piscataway, N.J.: IEEE Press, 2012, s. 282-289, artikel-id 6258534Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Smart buildings promise to revolutionize the way we live. Applications ranging from climate control to fire management can have significant impact on the quality and cost of these services. However, smart buildings and any technology with direct effect on human safety and life mustundergo extensive testing. Virtual testing by means of computer simulation can significantly reduce the cost of testing and, as a result, accelerate the development of novel applications. Unfortunately, building physically-accurate simulation codes can be labor intensive.To address this problem, we propose a framework for rapid, physically-accurate virtual testing. The proposed framework supports analytical modeling of both a discrete distributed system as well as the physical environment that hosts it. The discrete models supported are accurate enough to allow the automatic generation of a dedicated programming framework that will help the developer in the implementation of these systems. The physical environment models supported are equational specifications that are accurate enough to produce running simulation codes. Combined, these two frameworks enable simulating both active systems and physical environments. These simulations can be used to monitor the behavior and gather statistics about the performance of an application in the context of precise virtual experiments. To illustrate the approach, we present models of Heating, Ventilating and Air-Conditioning (HVAC) systems. Using these models, we construct virtual experiments that illustrate how the approach can be used to optimize energy and cost of climate control for a building. © 2012 IEEE.

Ort, förlag, år, upplaga, sidor
Piscataway, N.J.: IEEE Press, 2012. s. 282-289, artikel-id 6258534
Nyckelord [en]
Virtual testing, Smart buildings, HVAC, Pervasive computing
Nationell ämneskategori
Datorsystem
Identifikatorer
URN: urn:nbn:se:hh:diva-20919DOI: 10.1109/IE.2012.24Scopus ID: 2-s2.0-84866790681ISBN: 978-1-4673-2093-1 (tryckt)ISBN: 978-0-7695-4741-1 (digital)OAI: oai:DiVA.org:hh-20919DiVA, id: diva2:588230
Konferens
IE'12 International Conference on Intelligent Environments 8th International Conference on Intelligent Environments, IE 2012, Guanajuato, Mexico, June 26-28, 2012
Tillgänglig från: 2013-01-15 Skapad: 2013-01-14 Senast uppdaterad: 2018-03-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Taha, Walid

Sök vidare i DiVA

Av författaren/redaktören
Taha, Walid
Av organisationen
Centrum för forskning om inbyggda system (CERES)
Datorsystem

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 293 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf