Vital Sign Radar Redesign: Further Development of a Compact, Highly integrated 60 GHz Radar for Human Vital Sign Monitoring
Högskolan i Halmstad, Akademin för informationsteknologi.
Högskolan i Halmstad, Akademin för informationsteknologi.
2017 (Engelska)Självständigt arbete på avancerad nivå (magisterexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

Nowadays, thanks to the modern technologies, the human being has been able todevelop new techniques to solve problems present in the past. Regarding the medicalfield, it is common to use several apparatus in order to measure the vital signs. Themain drawback about the traditional methods employed for this purpose is that theyare invasive towards the patient. However, in this thesis it has been developed afurther design of a radar system so as to be able to measure these vital signs in awireless way.

Based on a 60 GHz frequency modulated continuous wave radar chip, it has been ableto increase the performance of the measurements by adding a second radar chip.Because of this new feature, the radar system is now having a better precision byprocessing greater data matrix to analyse the targets positions and theirmeasurements. In addition, an enhanced MCU has been incorporated in order toavoid performance bottlenecks because it is necessary to handle the processing of thedata received by the two radar chips. Lastly, reducing the sweeping time (periodbetween the lowest frequency broadcast to linearly reach the highest frequencybroadcast) from 20 ms the previous design to 1 ms, which requires higher samplingrate to cover the fast sweep and provide higher flow of information that leads to fasterdetection process.

A 3D design of the prototype has been designed to show the physical appearance itwould have once entering in production. The result is a compact and highlyintegrated radar system which will be able to monitor the heart beating andrespiration frequency of a human being in a range of ten meters.

Ort, förlag, år, upplaga, sidor
2017. , s. 69
Nyckelord [en]
radar, vital sign measuring, 60 Ghz frequency
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:hh:diva-34219OAI: oai:DiVA.org:hh-34219DiVA, id: diva2:1111147
Ämne / kurs
Elektronik
Utbildningsprogram
Magisterprogram i elektronikdesign
Handledare
Examinatorer
Tillgänglig från: 2017-06-20 Skapad: 2017-06-17 Senast uppdaterad: 2017-10-31Bibliografiskt granskad

Open Access i DiVA

fulltext(3398 kB)506 nedladdningar
Filinformation
Filnamn FULLTEXT03.pdfFilstorlek 3398 kBChecksumma SHA-512
c5d842e61851a1721cbf492dd26989dc419d41ac73c8fd92329bc299194232677f9d1a9290accf1f09f7aa66283bbcc42bb12a3d04aa4b5a5a7a68b3acdfed4d
Typ fulltextMimetyp application/pdf

Av organisationen
Akademin för informationsteknologi
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 541 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 934 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf