Vital Sign Radar Redesign: Further Development of a Compact, Highly integrated 60 GHz Radar for Human Vital Sign Monitoring
Högskolan i Halmstad, Akademin för informationsteknologi.
Högskolan i Halmstad, Akademin för informationsteknologi.
2017 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

Nowadays, thanks to the modern technologies, the human being has been able todevelop new techniques to solve problems present in the past. Regarding the medicalfield, it is common to use several apparatus in order to measure the vital signs. Themain drawback about the traditional methods employed for this purpose is that theyare invasive towards the patient. However, in this thesis it has been developed afurther design of a radar system so as to be able to measure these vital signs in awireless way.

Based on a 60 GHz frequency modulated continuous wave radar chip, it has been ableto increase the performance of the measurements by adding a second radar chip.Because of this new feature, the radar system is now having a better precision byprocessing greater data matrix to analyse the targets positions and theirmeasurements. In addition, an enhanced MCU has been incorporated in order toavoid performance bottlenecks because it is necessary to handle the processing of thedata received by the two radar chips. Lastly, reducing the sweeping time (periodbetween the lowest frequency broadcast to linearly reach the highest frequencybroadcast) from 20 ms the previous design to 1 ms, which requires higher samplingrate to cover the fast sweep and provide higher flow of information that leads to fasterdetection process.

A 3D design of the prototype has been designed to show the physical appearance itwould have once entering in production. The result is a compact and highlyintegrated radar system which will be able to monitor the heart beating andrespiration frequency of a human being in a range of ten meters.

sted, utgiver, år, opplag, sider
2017. , s. 69
Emneord [en]
radar, vital sign measuring, 60 Ghz frequency
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-34219OAI: oai:DiVA.org:hh-34219DiVA, id: diva2:1111147
Fag / kurs
Electronics
Utdanningsprogram
Master's Programme in Electronics Design, 60 credits
Veileder
Examiner
Tilgjengelig fra: 2017-06-20 Laget: 2017-06-17 Sist oppdatert: 2017-10-31bibliografisk kontrollert

Open Access i DiVA

fulltext(3398 kB)208 nedlastinger
Filinformasjon
Fil FULLTEXT03.pdfFilstørrelse 3398 kBChecksum SHA-512
c5d842e61851a1721cbf492dd26989dc419d41ac73c8fd92329bc299194232677f9d1a9290accf1f09f7aa66283bbcc42bb12a3d04aa4b5a5a7a68b3acdfed4d
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 243 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 563 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf