hh.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
AdaptoCell – Microfluidic Platforms at MAX IV Laboratory
MAX IV Laboratory, Lund University, Lund, Sweden.
MAX IV Laboratory, Lund University, Lund, Sweden; Ludwig-Maximilians-Universität München, München, Germany.
MAX IV Laboratory, Lund University, Lund, Sweden.
MAX IV Laboratory, Lund University, Lund, Sweden.
Visa övriga samt affilieringar
2021 (Engelska)Konferensbidrag, Muntlig presentation med publicerat abstract (Refereegranskat)
Abstract [en]

In the AdaptoCell project, we are developing microfluidic platforms for X-ray studies of liquid samples. Microfluidics is a suitable technology for samples that are prone to radiation damage, such as proteins. By having the sample underflow, the sample is continuously refreshed, and the risk of radiation damage is reduced. The technology is also suitable for investigating dynamic events such as in situ mixing. The microfluidic platforms are being integrated at three beamlines at MAX IV Laboratory: Balder (X-ray absorption/emission spectroscopy), CoSAXS (small angle x-ray scattering) and MicroMAX (serial synchrotron crystallography). Currently, the platforms are available for users at Balder and CoSAXS, which is under development at MicroMAX. In addition, we also provide a microfluidic offline test station where users can test their samples and optimise their devices before the beam time. The main components of the microfluidic setup are the pressure-driven flow controller and the microfluidic chip. We mainly use commercially available polymer microfluidic chips made of COC (cyclic olefin copolymer). COC is used as a chip material as it has high X-ray transmission and high resistance to radiation damage. There are several different chip designs available such as straight channel chips, droplet generator chips and mixing chips. We believe the AdaptoCell platforms will be useful and versatile sample environments for academic and industrial users at MAX IV Laboratory who want to perform experiments with liquid samples under flow. 

Ort, förlag, år, upplaga, sidor
2021.
Nationell ämneskategori
Subatomär fysik
Forskningsämne
Smarta städer och samhällen
Identifikatorer
URN: urn:nbn:se:hh:diva-47662OAI: oai:DiVA.org:hh-47662DiVA, id: diva2:1686171
Konferens
33rd MAX IV User Meeting, 25-27 Oct., 2021
Projekt
AdaptoCell
Forskningsfinansiär
Stiftelsen för strategisk forskning (SSF), ITM-0375Tillgänglig från: 2022-08-08 Skapad: 2022-08-08 Senast uppdaterad: 2025-02-14Bibliografiskt granskad

Open Access i DiVA

Max IV User Meeting 33rd(818 kB)70 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 818 kBChecksumma SHA-512
ff4c06b144644533ff93f686b05dbdca2acc71dfc7122a33ff40ceb78002dc87a07dc2b46dfee08429d80667c7fea0d00c3b818544d6a319f5e55e94910700fe
Typ fulltextMimetyp application/pdf

Person

Friel, R. J.

Sök vidare i DiVA

Av författaren/redaktören
Friel, R. J.
Av organisationen
Akademin för informationsteknologi
Subatomär fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 70 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 171 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf