hh.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Novel low temperature heat distribution technology
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap, Rydberglaboratoriet för tillämpad naturvetenskap (RLAS).ORCID-id: 0000-0003-2885-0923
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap, Rydberglaboratoriet för tillämpad naturvetenskap (RLAS).ORCID-id: 0000-0001-9069-0807
2018 (Engelska)Ingår i: Energy, ISSN 0360-5442, E-ISSN 1873-6785, Vol. 145, s. 526-539Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Lower future heat demands and lower availability of non-fossil high temperature heat supply are expected future market conditions that restrain the long-term viability of contemporary district heating systems. Hence, current district heating technology should be enhanced to increase system performance in new heat distribution areas. This paper aims to outline a proposal for technical improvements required to achieve lower annual average return temperatures in new residential buildings to improve viability in future market conditions. The proposed technical solution consists of three principle changes: three-pipe distribution networks, apartment substations, and longer thermal lengths for heat exchangers. The three technical modifications aims at addressing system embedded temperature errors. Furthermore, a simulation model was developed to assess the proposed technical solution concerning different energy performances of buildings and different thermal lengths in heat exchangers. The results show that implementation of the three technical modifications reaches time-weighted annual average return temperatures of 17–21 °C with supply temperatures of about 50 °C. The results also verify the increased necessity to separate the network return flows into delivery and recirculation flows in residential substations as energy performance in buildings increase.

Ort, förlag, år, upplaga, sidor
London: Elsevier, 2018. Vol. 145, s. 526-539
Nyckelord [en]
Low temperature, District heating, Three-pipe system, Recirculation, 4GDH-3P
Nationell ämneskategori
Energiteknik
Identifikatorer
URN: urn:nbn:se:hh:diva-38360DOI: 10.1016/j.energy.2017.12.157OAI: oai:DiVA.org:hh-38360DiVA, id: diva2:1263919
Tillgänglig från: 2018-11-18 Skapad: 2018-11-18 Senast uppdaterad: 2019-04-04Bibliografiskt granskad
Ingår i avhandling
1. Enhanced District Heating Technology: Maintaining Future System Feasibility
Öppna denna publikation i ny flik eller fönster >>Enhanced District Heating Technology: Maintaining Future System Feasibility
2017 (Engelska)Licentiatavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

When heat demand and high temperature heat supply gradually decreases in the future, then it will effect district heating systems ability to compete on the heat market. A good way to mitigate less district heating feasibility is to operate systems with lower temperature levels and the most conceivable way to achieve lower temperature levels is to decrease return temperatures.

Thus, this thesis emphasise temperature errors embedded in district heating systems. Only a selection of temperature errors are analysed in this thesis. First, the temperature error that occurs due to recirculation in distribution networks at low heat demands. Second, the temperature error that occurs due to hot water circulation in multi-family buildings. Third, the temperature error that occurs due to less than possible heat transfer in heat exchangers, i.e. too short thermal lengths.

In order to address these temperature errors three technology changes have been proposed (i) three-pipe distribution network to separate the recirculation return flow from the delivery return flow, (ii) apartment substations to eliminate hot water circulation utilisation, and (iii) improved heat exchangers for lower return temperatures at a constant scenario. Analysis of proposed changes has resulted in annual average return temperatures between 17-21 °C.

Furthermore, rapid introduction of intermittent renewable electricity supply in the energy system has prompted an increased necessity of power system balancing capacities. Large-scale conversion of power-to-heat in electric boilers and heat pumps is a feasible alternative to achieve such balancing capacities. Analysis of the unique Swedish experience with utilisation of large heat pumps installations connected to district heating systems show that since the 1980s 1527 MW of heat power has been installed, about 80 % of the capacity was still in use by 2013. Thus, a cumulative value of over three decades of operation and maintenance exists within Swedish district heating systems.

The two papers presented in this thesis are related to future district heating systems through the five abilities of fourth generation district heating (4GDH), which are documented in the definition paper of 4GDH.

Ort, förlag, år, upplaga, sidor
Lund: Lund University Open Access, 2017. s. 75
Nationell ämneskategori
Energiteknik
Identifikatorer
urn:nbn:se:hh:diva-39199 (URN)978-91-7753-507-2 (ISBN)978-91-7753-508-9 (ISBN)
Presentation
2017-12-18, M:B (M-huset), Ole Römers väg 1, Lund, 13:15 (Engelska)
Opponent
Handledare
Anmärkning

Med populärvetenskaplig sammanfattning på svenska. I publikationen felaktigt: ISSN 0282-1990

Tillgänglig från: 2019-04-04 Skapad: 2019-04-04 Senast uppdaterad: 2019-04-04Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Averfalk, HelgeWerner, Sven

Sök vidare i DiVA

Av författaren/redaktören
Averfalk, HelgeWerner, Sven
Av organisationen
Rydberglaboratoriet för tillämpad naturvetenskap (RLAS)
I samma tidskrift
Energy
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 120 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf