Alternative discharge methods of HVDC cables for a DC test
2017 (Engelska)Självständigt arbete på avancerad nivå (masterexamen), 40 poäng / 60 hpStudentuppsats (Examensarbete)
Abstract [en]

The purpose of this thesis is to analyse alternative discharging methods of HVDC cables for a DC test in a real situation. It is necessary to research relevant data and consult contacts in order to solve the task. The project is based on the implementation of a developed system on the testing object and preceded by tests in the High Voltage Laboratory in Karlskrona. Simultaneously the main requirement is to completely exclude any human contribution in the discharging process of the DC cable and to maintain the highest safety standards in line with ABB policy. Currently the discharge process after DC testing is completed manually.

Testing is carried out by increasing the voltage until the test voltage is reached and kept constant throughout the test period. Followed by switching off the voltage and allowing the cable to initially self-discharge, before it forces the discharge through the discharging water resistor. When the voltage is zero, cable termination ground by providing a secure grounding. Initially the cable charges out through self-discharge and this must continue down to the Uo. To avoid damaging the test object by maintaining the voltage for too long, discharge can begin after 45 minutes if the voltage drops below under 1,2 Uo. The forced discharge occurs by an earth rod connecting the discharge resistance to the ground.

Past tests have shown the occasional use of a linked up Water Conditioning Unit system consisting of the pump and filters to ground out by hoses filled with deionized water. This method has been reviewed and modernized which made it more accessible and reliable.

Ort, förlag, år, upplaga, sidor
2017.
Nyckelord [en]
HVDC, cable, cables, high, voltage, testing
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:hh:diva-35315OAI: oai:DiVA.org:hh-35315DiVA, id: diva2:1154532
Utbildningsprogram
Magisterprogram i energiteknik - förnybar energi
Presentation
(Engelska)
Handledare
Examinatorer
Tillgänglig från: 2017-11-06 Skapad: 2017-11-02 Senast uppdaterad: 2017-11-06Bibliografiskt granskad

Open Access i DiVA

fulltext(1689 kB)591 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 1689 kBChecksumma SHA-512
bddfd41306f91f20dddaf0f839ed884a0106697072f30be07fa5ed7a81ce33eda8038c5ee316f782fd83c81482e1de72a7ef4c5fc2d4ebd3e7d5ffd0e7bfe01d
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Luszczynski, Jakub
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 591 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 241 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf