hh.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Utveckling av metod för benkvalitetsmätning
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap.
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap.
2017 (Svenska)Självständigt arbete på grundnivå (kandidatexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)Alternativ titel
Utveckling av metod för benkvalitetsmätning (Svenska)
Abstract [en]

Dental implant surgery is performed daily to replace single teeth and entire tooth rows. Implant selection is based on the bone quality of the cortical and trabecular bone in the jaw bone. Usually, the surgeon assesses the bone quality subjectively during drilling in the jaw bone. The aim of this project has been to increase the ability to give the surgeon a direct feedback on the bone quality during threading in a pre-drilled hole, so the right type of dental implant can be chosen. The idea of the project comes from Lennart Carlsson at TL Medical AB, who has developed a custom-made tap that is used together with a drilling machine that measures the torque during threading. Carlsson has done measurements in polyurethane foam with densities of 1050, 500 and 300 kg/m3.

 

Through regression analyzes in MATLAB on Carlsson's measurements, a linear relationship between torque and number of turns the tap has threaded the material was found. The mean slope value of thirteen measurements/density ± SD was 8.0 ± 0.5 Ncm for density 1050 kg / m3. For density 500 kg / m3 the mean was 1.1 ± 0.2 Ncm and for density 300 kg / m3, the mean was 0.3 ± 0.1 Ncm. The relationship varied depending on which density that was investigated but the lowest achieved R2 value was 0.7. The project has resulted in a table of bone quality and maximum torque. The various ranges for maximum torques were divided into bone qualities as follows: Quality 1 ≥ 26 Ncm, 20 < Quality 2 < 26 Ncm, 12 < Quality 3 ≤ 20 Ncm and Quality 4 ≤ 12 Ncm. Own measurements in ribs from calf were performed to compare the results from the table with the reality. Five measurements out of 11 were in accordance with the table regarding bone quality while the other measurements were either one classification higher or one classification lower than the table.

 

The most important findings are the relationship between the torque size during threading and the different material densities and that the custom-made tap produces a linearly increasing torque for each cut threading in the material. The project group realizes that more tests would have to be done, especially on human tissue, to validate the developed bone quality scale.

Ort, förlag, år, upplaga, sidor
2017. , s. 40
Nyckelord [sv]
tandimplantat, benkvalité, gängtapp
Nationell ämneskategori
Maskinteknik
Identifikatorer
URN: urn:nbn:se:hh:diva-33992OAI: oai:DiVA.org:hh-33992DiVA, id: diva2:1106065
Externt samarbete
Lennart Carlsson
Ämne / kurs
Maskinteknik
Handledare
Examinatorer
Tillgänglig från: 2017-06-21 Skapad: 2017-06-06 Senast uppdaterad: 2017-06-21Bibliografiskt granskad

Open Access i DiVA

fulltext(2169 kB)118 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 2169 kBChecksumma SHA-512
1d443ad8f882eb82bd413d2e1841b5a70e151ee688661b73aef316fc5a0618a9452f878ede0fec704ef795219e3aaa7efde4266e306e6e9cbbeea2f7228217da
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Eriksson, AnnaCarlfjord, Salli
Av organisationen
Akademin för ekonomi, teknik och naturvetenskap
Maskinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 118 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 139 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf