A study on the bond behavior of different FRCM systems
Qatar University, Doha, Qatar.ORCID-id: 0000-0003-2273-6863
Qatar University, Doha, Qatar.
2018 (engelsk)Inngår i: MATEC Web of Conferences, 2018, Vol. 199, artikkel-id 09003Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Fabric-reinforced cementitous matrix (FRCM) composites are usually applied on the concrete surface for the purpose of strengthening reinforced concrete structures. However, the efficiency of FRCM strengthening is notably affected by the bond between the FRCM system and concrete substrate. In view of that, the current paper presents the results of a preliminary experimental study carried out to investigate the bond characteristics between FRCM composites and concrete. Six number of specimens, each consisted of a 150-mm concrete cube with a double-shear connection to an FRCM system, were subjected to direct-shear loading test. The parameters investigated include (a) FRCM material (carbon, polyparaphenylene benzobisoxazole (PBO), and glass); and (b) Bond length (75 mm or 100 mm). The FRCM systems typically included a single layer of fabric with the associated mortar, and the bond width was uniformly taken as 100 mm. The test results revealed that the bond capacity is enhanced with an increase in the FRCM bonded length. The PBO-FRCM showed the highest bond capacity between FRCM composite and concrete substrate among the three systems. The modes of failure observed in carbon-, PBO-, and glass-FRCM bond tests are fabric delamination, FRCM mortar/concrete debonding, and fabric rapture, respectively. The PBOand glass-FRCM bond tests thus exhibited a more brittle behavior at failure than that of the carbon-FRCM counterpart.© The Authors, published by EDP Sciences, 2018

sted, utgiver, år, opplag, sider
2018. Vol. 199, artikkel-id 09003
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-49001DOI: 10.1051/matecconf/201819909003Scopus ID: 2-s2.0-85056640244OAI: oai:DiVA.org:hh-49001DiVA, id: diva2:1721350
Konferanse
International Conference on Concrete Repair, Rehabilitation and Retrofitting (ICCRRR 2018), Cape Town, South Africa, November 19-21, 2018
Tilgjengelig fra: 2022-12-21 Laget: 2022-12-21 Sist oppdatert: 2023-02-16bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Younis, Adel

Søk i DiVA

Av forfatter/redaktør
Younis, Adel

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 2 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf