Alternative discharge methods of HVDC cables for a DC test
2017 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 40 poäng / 60 hpOppgave
Abstract [en]

The purpose of this thesis is to analyse alternative discharging methods of HVDC cables for a DC test in a real situation. It is necessary to research relevant data and consult contacts in order to solve the task. The project is based on the implementation of a developed system on the testing object and preceded by tests in the High Voltage Laboratory in Karlskrona. Simultaneously the main requirement is to completely exclude any human contribution in the discharging process of the DC cable and to maintain the highest safety standards in line with ABB policy. Currently the discharge process after DC testing is completed manually.

Testing is carried out by increasing the voltage until the test voltage is reached and kept constant throughout the test period. Followed by switching off the voltage and allowing the cable to initially self-discharge, before it forces the discharge through the discharging water resistor. When the voltage is zero, cable termination ground by providing a secure grounding. Initially the cable charges out through self-discharge and this must continue down to the Uo. To avoid damaging the test object by maintaining the voltage for too long, discharge can begin after 45 minutes if the voltage drops below under 1,2 Uo. The forced discharge occurs by an earth rod connecting the discharge resistance to the ground.

Past tests have shown the occasional use of a linked up Water Conditioning Unit system consisting of the pump and filters to ground out by hoses filled with deionized water. This method has been reviewed and modernized which made it more accessible and reliable.

sted, utgiver, år, opplag, sider
2017.
Emneord [en]
HVDC, cable, cables, high, voltage, testing
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-35315OAI: oai:DiVA.org:hh-35315DiVA, id: diva2:1154532
Utdanningsprogram
Master's Programme in Renewable Energy Systems, 60 credits
Presentation
(engelsk)
Veileder
Examiner
Tilgjengelig fra: 2017-11-06 Laget: 2017-11-02 Sist oppdatert: 2017-11-06bibliografisk kontrollert

Open Access i DiVA

fulltext(1689 kB)589 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 1689 kBChecksum SHA-512
bddfd41306f91f20dddaf0f839ed884a0106697072f30be07fa5ed7a81ce33eda8038c5ee316f782fd83c81482e1de72a7ef4c5fc2d4ebd3e7d5ffd0e7bfe01d
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Luszczynski, Jakub

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 589 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 241 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf