Reduction of heat loss for an immersion heater
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap, Centrum för innovations-, entreprenörskaps- och lärandeforskning (CIEL), Sustainability, Innovation and Management in Building (SIMB).
2017 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

In this study, an electrical immersion heater mounted on a water tank has been investigated. Themain aim was to reduce heat transfer and to utilize the maximum energy available from heater toheat the water. To observe the effects of essential geometrical and operating parameters on thesystem performance, different computational test cases were run for three different designs.In the first case of simulation, the immersion heater of existing design mounted on a water tankhas been analyzed. The cold-water tank with inlet and outlet and given appropriate boundaryconditions was used to see the temperature contours inside the water tank and temperature of theimmersion layer itself.In the second case, an insulation plate has been introduced in the immersion heater head in orderto reduce heat loss by considering the possible heat leakage through the gap inside the heaterhead by radiation.In the third case, an insulation ring has been introduced in the immersion heater head as asubstitute for the insulation plate which has the same aim as second case.The results obtained from the CFD simulation shows the thermal performance of immersionheater in a water tank for three different cases. The results are helpful in optimizing both heatingelement and immersion heater by introducing different changes to optimize the design. It showsthat the redesigned immersion heater and storage tank can provide improved working conditions.Also, at early design stages, CFD simulations could be used as an effective tool to optimizethermal storage tank parameters, so it may add value to the storage tank and immersion heaterperformance and efficiency, by optimizing the whole thermal heating system design and size.Different materials and geometry design are tested giving the minimum heat losses from thesystem and uniform temperature distribution in the water heater.

sted, utgiver, år, opplag, sider
2017. , s. 58
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-35271OAI: oai:DiVA.org:hh-35271DiVA, id: diva2:1152917
Fag / kurs
Mechanical Engineering
Utdanningsprogram
Master's Programme in Mechanical Engineering, 60 credits
Presentation
2017-09-26, P321, Halmstad University, Kristian IV:s väg 3, Halmstad, 16:12 (engelsk)
Veileder
Examiner
Tilgjengelig fra: 2017-11-01 Laget: 2017-10-26 Sist oppdatert: 2018-05-23bibliografisk kontrollert

Open Access i DiVA

fulltext(2479 kB)517 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 2479 kBChecksum SHA-512
765f6ceb50812fa047a4f93b2bee36e8abc3424cbc2a974c648d88a28382beae499e4cac259aad04d74099447ef228510168b36f343c46023cddba3c35ef6dc9
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 517 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 357 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf