Pipe Sizing for Novel Heat Distribution Technology
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap, Rydberglaboratoriet för tillämpad naturvetenskap (RLAS).ORCID-id: 0000-0003-2885-0923
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap, Rydberglaboratoriet för tillämpad naturvetenskap (RLAS).
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap, Rydberglaboratoriet för tillämpad naturvetenskap (RLAS).ORCID-id: 0000-0001-9069-0807
2019 (engelsk)Inngår i: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 12, nr 7, artikkel-id 1276Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper assesses pipe sizing aspects for previously proposed, novel, low heat distribution technology with three pipes. Assessment issues include heat loss, pressure loss, and pipe sizing for different typical pipe configurations. This assessment has been provided by the analysis of a case area with single-family houses. Concerning heat loss, the proposed three-pipe solutions have the same magnitude of heat loss as conventional twin pipes, since lower return temperatures compensate for the larger heat loss area from the third pipe. Regarding pressure loss, the main restriction on the size of the third pipe is limited to the pressure loss in the third pipe. Thermostatic valves to manage the flow rate of the third pipe are advocated, since alternative small pumps have not been found to be commercially available. The pipe sizing recommendation is that the third pipe for recirculation purposes can be two to three standard pipe sizes smaller than the corresponding supply and return pipe, if no prosumer is connected in the heat distribution network.

sted, utgiver, år, opplag, sider
Basel: MDPI, 2019. Vol. 12, nr 7, artikkel-id 1276
Emneord [en]
low temperature, district heating, pressure gradients, three-pipe system, 4GDH-3P
HSV kategori
Identifikatorer
URN: urn:nbn:se:hh:diva-39198DOI: 10.3390/en12071276ISI: 000465561400093Scopus ID: 2-s2.0-85065515173OAI: oai:DiVA.org:hh-39198DiVA, id: diva2:1302256
Prosjekter
TEMPO
Forskningsfinansiär
EU, Horizon 2020, 768936Tilgjengelig fra: 2019-04-04 Laget: 2019-04-04 Sist oppdatert: 2020-02-18bibliografisk kontrollert
Inngår i avhandling
1. Low-temperature District Heating: Various Aspects of Fourth-generation Systems
Åpne denne publikasjonen i ny fane eller vindu >>Low-temperature District Heating: Various Aspects of Fourth-generation Systems
2019 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

With decreasing heat demand and less availability of high-temperature heat supply in future energy systems, the current district heating systems may experience increased competition on the heat market. A viable option to mitigate increasing competition is to operate systems with lower temperature levels, and the most conceivable way to achieve lower temperature levels is to decrease return temperatures.In this thesis, aspects of improvements in district heating systems are assessed. Three aspects, in particular, have been analysed. These are integration between energy systems, improvements in heat distribution technology, and economic benefits of low-temperature district heating systems.An increasing interest in integrating different energy systems has been prompted by the rapid introduction of intermittent renewable electricity supply in the energy system. Large-scale conversion of power to heat in electric boilers and heat pumps is a feasible alternative to achieve the balancing capacities required to maintain system functioning. Analysis of the unique Swedish experience using large heat-pump installations connected to district heating systems shows that, since the 1980s, 1527 MW of heat power has been installed, and about 80% of the capacity was still in use in 2013. Thus, a cumulative value of over three decades of operation and maintenance exists within Swedish district heating systems.Increased competition prompted by changes in the operation environment necessitates improved heat distribution. This thesis focuses on three system-embedded temperature errors: first, the temperature error that occurs due to recirculation in distribution networks at low heat demands; second, the temperature error that occurs due to hot-water circulation in multi-family buildings; third, the temperature error that occurs due to lower heat transfer than is possible in heat exchangers (i.e. too-short thermal length). To address these temperature errors, three technology changes have been proposed (i) a three-pipe distribution network to separate the recirculation return flow from the delivery return flow, (ii) apartment substations to eliminate hot-water circulation use, and (iii) improved heat exchangers for lower return temperatures. The analysis of the proposed changes indicates annual average return temperatures between 17°C and 21°C.The final analysed aspect is the economic benefits of low-temperature district heating. It was identified that strong economic motives for lower operating temperatures in future heat supply exist, whereas the economic motives are significantly weaker for the traditional heat supply.The five papers presented in this thesis are related to future district heating systems through the five abilities of fourth-generation district heating (4GDH), which are documented in the definition paper on 4GDH.

sted, utgiver, år, opplag, sider
Lund: Lund University, 2019. s. 31
Emneord
District heating, low temperature, three-pipe systems, 4GDH-3P
HSV kategori
Identifikatorer
urn:nbn:se:hh:diva-41080 (URN)978-91-7895-316-5 (ISBN)978-91-7895-317-2 (ISBN)
Disputas
2019-12-11, M:B, M-huset, Ole Römers väg 1, Lund, 13:15 (engelsk)
Opponent
Veileder
Merknad

ISRN: LUTMDN/TMHP-19/1153-SE. I publikationen felaktigt: ISSN 0282-1990

Tilgjengelig fra: 2020-02-18 Laget: 2019-12-03 Sist oppdatert: 2020-02-18

Open Access i DiVA

Pipe Sizing for Novel Heat Distribution Technology(1800 kB)69 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1800 kBChecksum SHA-512
f9182c13ec5e7c33e4e1fe239b6d550f3527d6c12c083cc6f5f910ecaf9daea49fbea9573a93b678834d2b3ec030a3cb77b96d4aa5f688a2da0311c5df582092
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Averfalk, HelgeOttermo, FredricWerner, Sven

Søk i DiVA

Av forfatter/redaktør
Averfalk, HelgeOttermo, FredricWerner, Sven
Av organisasjonen
I samme tidsskrift
Energies

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 69 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 181 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf