Vertical Axis Wind Turbines: Tower Dynamics and Noise
Högskolan i Halmstad, Akademin för ekonomi, teknik och naturvetenskap, Bio- och miljösystemforskning (BLESS), Energiteknik.ORCID-id: 0000-0001-9982-5317
2015 (Engelska)Licentiatavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Vertical axis wind turbines (VAWTs) have with time been outrivaled by the today common and economically feasible horizontal axis wind turbines (HAWTs). However, VAWTs have several advantages such as the possibility to put the drive train at ground level, lower noise emissions and better scaling behavior which still make them interesting for research.

The work within this thesis is made in collaboration between the Department of Construction and Energy Engineering at Halmstad University and the Division for Electricity at Uppsala University. A 200 kW VAWT owned by the latter and situated close to Falkenberg in the southwest of Sweden has been the main subject of the research even if most learnings has been generalized to fit a typical vertical turbine. This particular turbine has a wooden tower which is semi-guy-wired, i.e. the tower is both firmly attached to the ground and supported by guy-wires.

This thesis has two main topics both regarding VAWTs: eigenfrequency of the tower and the noise generated from the turbine. The eigenfrequency of a semi-guy-wired tower is studied and an analytical expression describing this is produced and verified by experiments and simulations. The eigenfrequency of the wire itself and how it is affected by wind load are also studied.  The noise characteristics of VAWTs have been investigated, both theoretically and by noise measurement campaigns. Both noise emission and frequency distribution of VAWTs has been studied.

The work has resulted in analytical expressions for tower and wire eigenfrequency of a semi-guy-wired tower as well as recommendations for designing future towers for VAWTs. The noise emission of VAWTs has been studied and proven low compared to HAWTs. The noise frequency distribution of the 200 kW VAWT differs significantly from that of a similar size HAWTs with for example lower levels for frequencies below 3000 Hz.

Ort, förlag, år, upplaga, sidor
Uppsala: Uppsala universitet, 2015. , 61 s.
Serie
UURIE / Uppsala universitet, Institutitionen för teknikvetenskaper, ISSN 0349-8352 ; 340-15L
Nyckelord [en]
VAWT, H-rotor, eigenfrequency, semi-guy-wired tower, noise emission, sound power level
Nationell ämneskategori
Energiteknik
Identifikatorer
URN: urn:nbn:se:hh:diva-27526OAI: oai:DiVA.org:hh-27526DiVA: diva2:781905
Presentation
2015-01-16, Polhemsalen, Ångströmlaboratoriet, Uppsala, 13:43 (Engelska)
Opponent
Handledare
Forskningsfinansiär
StandUp
Tillgänglig från: 2015-01-22 Skapad: 2015-01-19 Senast uppdaterad: 2015-02-18Bibliografiskt granskad
Delarbeten
1. Eigen Frequencies of A Vertical Axis Wind Turbine Tower Made of Laminated Wood and the Effect Upon Attaching Guy Wires
Öppna denna publikation i ny flik eller fönster >>Eigen Frequencies of A Vertical Axis Wind Turbine Tower Made of Laminated Wood and the Effect Upon Attaching Guy Wires
2014 (Engelska)Ingår i: Wind Engineering: The International Journal of Wind Power, ISSN 0309-524X, E-ISSN 2048-402X, Vol. 38, nr 3, 277-290 s.Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Eigen frequencies of a vertical axis wind turbine tower made out of laminated wood which are both bolted to the ground and supported by guy wires are studied and compared. Using beam theory, an analytical model taking the guy wires into account for calculating the first mode eigen frequency of the tower has been derived. The analytical model is then evaluated by comparing with FEM-simulations and measurements performed on the actual tower. The model is found to be reasonably accurate keeping in mind that the estimated masses and second moments of area are somewhat rough. Furthermore the model can be used to give an indication of the magnitude of change in eigen frequency when modifying a tower or guy wire property.

Ort, förlag, år, upplaga, sidor
Brentwood, United Kingdom: Multi-Science Publishing, 2014
Nyckelord
VAWT, Vertical Axis Wind Turbine, Semi-guy-wired, Natural frequency, Eigen frequency, Resonance
Nationell ämneskategori
Energiteknik
Identifikatorer
urn:nbn:se:hh:diva-25467 (URN)10.1260/0309-524X.38.3.277 (DOI)2-s2.0-84901792518 (Scopus ID)
Forskningsfinansiär
StandUp
Tillgänglig från: 2014-06-02 Skapad: 2014-06-02 Senast uppdaterad: 2017-12-05Bibliografiskt granskad
2. Avoidance of resonances in a semi-guy-wired vertical axis wind turbine
Öppna denna publikation i ny flik eller fönster >>Avoidance of resonances in a semi-guy-wired vertical axis wind turbine
2014 (Engelska)Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Resonance analysis for a vertical axis wind turbine is performed. The turbine may be described as semi-guy wired, being bolted stiffly to the ground as well as supported by guy wires. The influence of the first mode eigen frequency of the guy wires and how it is affected by wind load is examined. Using beam theory, an analytical model for calculating the first mode eigen frequency of the guy wire for different wind loads is derived. The analytical model is verified with FEM-simulations and then used to assemble a diagram showing how to combine the wire size, inclination angle and pre-tension for an eigen frequency range over the 3P load for nominal rotational speed and for a certain effective spring force acting on the tower. This diagram, here called an EA-T diagram, may be used as a quick tool for comparing wire setups and a similar diagram can be used for other guy wired structures.

Nyckelord
VAWT, guy wire, semi-guy-wired, resonance, eigen frequency, natural frequency
Nationell ämneskategori
Energiteknik
Identifikatorer
urn:nbn:se:hh:diva-24884 (URN)
Konferens
EWEA 2014 - European Wind Energy Association – Annual Event (Conference), Barcelona, Spain, 10-13 March, 2014
Forskningsfinansiär
StandUp
Tillgänglig från: 2014-03-19 Skapad: 2014-03-19 Senast uppdaterad: 2017-05-10Bibliografiskt granskad
3. Noise Propagation from a Vertical Axis Wind Turbine
Öppna denna publikation i ny flik eller fönster >>Noise Propagation from a Vertical Axis Wind Turbine
Visa övriga...
2014 (Engelska)Ingår i: Proceedings of 43rd International Congress on Noise Control Engineering: Internoise 2014 / [ed] John Davy, Charles Don, Terry McMinn, Liz Dowsett, Norm Broner & Marion Burgess, Brisbane, QLD: Australian Acoustical Society , 2014Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Initial noise measurements were performed on a 200kW vertical axis wind turbine (VAWT) and results were compared to that of a Vestas V27, a similar size horizontal axis wind turbine (HAWT). Multiple recording units were placed in line downwind of the turbine to investigate noise propagation. The frequency distribution of the noise were analyzed indicating that the VAWT has lower relative levels for frequencies under 3000 Hz, especially within 600-1200 Hz. Furthermore, VAWT noise seems to occur more around the same frequencies as the natural background noise, increasing masking probability. Results from propagation measurements seemed to indicate that noise declines more rapidly with distance for the VAWT then for the reference HAWT, possibly explained by the lower levels at low frequencies. Further investigation is needed to establish these differences and the 200 kW VAWT creates an opportunity doing so utilizing arguably the largest operational VAWT existing today.

Ort, förlag, år, upplaga, sidor
Brisbane, QLD: Australian Acoustical Society, 2014
Nyckelord
VAWT, Wind Turbine, Propagation
Nationell ämneskategori
Energiteknik
Identifikatorer
urn:nbn:se:hh:diva-27107 (URN)2-s2.0-84923595295 (Scopus ID)978-0-909882-02-0 (ISBN)978-0-909882-03-7 (ISBN)978-0-909882-04-4 (ISBN)
Konferens
inter.noise 2014, 43rd International Congress on Noise Control Engineering, Melbourne, Australia, November 16-19, 2014
Forskningsfinansiär
StandUp
Tillgänglig från: 2014-11-25 Skapad: 2014-11-25 Senast uppdaterad: 2017-05-10Bibliografiskt granskad
4. Noise Emission of a 200 kW Vertical Axis Wind Turbine
Öppna denna publikation i ny flik eller fönster >>Noise Emission of a 200 kW Vertical Axis Wind Turbine
2016 (Engelska)Ingår i: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 9, nr 1, 19Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The noise emission from a vertical axis wind turbine (VAWT) has been investigated. A noisemeasurement campaign on a 200 kW straight-bladed VAWT has been conducted, and the result hasbeen compared to a semi-empirical model for turbulent-boundary-layer trailing edge (TBL-TE) noise.The noise emission from the wind turbine was measured, at wind speed 8 m/s, 10 m above ground, to96.2 dBA. At this wind speed, the turbine was stalling as it was run at a tip speed lower than optimaldue to constructional constraints. The noise emission at a wind speed of 6 m/s, 10 m above groundwas measured while operating at optimum tip speed and was found to be 94.1 dBA. A comparisonwith similar size horizontal axis wind turbines (HAWTs) indicates a noise emission at the absolutebottom of the range. Furthermore, it is clear from the analysis that the turbulent-boundary-layertrailing-edge noise, as modeled here, is much lower than the measured levels, which suggests thatother mechanisms are likely to be important, such as inflow turbulence.

Ort, förlag, år, upplaga, sidor
Basel: MDPI, 2016
Nyckelord
vertical axis wind turbine (VAWT), H-rotor, noise, noise emission, sound power level
Nationell ämneskategori
Energiteknik
Identifikatorer
urn:nbn:se:hh:diva-27523 (URN)10.3390/en9010019 (DOI)000369501500013 ()2-s2.0-84956619748 (Scopus ID)
Forskningsfinansiär
StandUp
Tillgänglig från: 2015-01-19 Skapad: 2015-01-19 Senast uppdaterad: 2017-12-05Bibliografiskt granskad

Open Access i DiVA

fulltext(9127 kB)3182 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 9127 kBChecksumma SHA-512
79dbed675f5da62f54c30934b03a6beccf246b78affc788ea889082284be6eb83c8fb5e88824abe3d42447fce811db51a1909f5423ba47f9b6bf2a21dfc4b72d
Typ fulltextMimetyp application/pdf

Personposter BETA

Möllerström, Erik

Sök vidare i DiVA

Av författaren/redaktören
Möllerström, Erik
Av organisationen
Energiteknik
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 3182 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 829 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf